DT-900 Series  DUAL TEC
® 
Motion Sensor for Commercial
and Light Industrial Applications—Installation Instructions
Step 1
Select mounting height.
Step 2
Carefully push screwdriver into slots
to disengage latches and open top
cover.
Step 3
Firmly insert screwdriver into slot in
arrow and rotate PIR Mirror Selector
to the correct range.
Step 5
Locate correct sensor range scale
and rotate Vertical Adjustment Screw
until the diamond corresponds to the
sensor mounting height (coarse
adjust).
Step 6
Set switch S3 to establish the sensi-
tivity best suited to your application.
Step 7
Select INFORMER
®
 mode with switch
S2, if desired. (See Supplemental
Information).
SENSITIVITY
HIGH
LOW
H
N*
L**
S3
NORMAL
*Factory default setting. **Not connected
Step 8
Carefully push screwdriver into slot
to disengage latch and remove
bottom cover.
Step 9
Unfasten screws and remove mount-
ing plate from sensor.
Step 10
Attach mounting plate to wall at
desired height, using four fasteners
(not supplied).
Step 11
Pull about 30 cm (12”) of wire from
wall through the opening in the
mounting plate and route wire to the
terminal strip.
Step 12
Hang the sensor on the mounting
plate hooks and fasten with the two
mounting plate screws.
Step 13
Wire the unit as shown.
Use 2.0 - 0.3 mm
2
(14-22 AWG).
NOTE:  Secure wires to mounting plate with tie wraps.
Step 14
Loosen horizontal locking screw in
sensor support base.
Step 15
Grasp housing and rotate it to the
desired position (coarse adjust).  If
fine adjust is needed see Steps 20-
22.
NOTE:  Reference marks = 5° change.
Step 16
Apply power to sensor and prepare
for walk-test.
Step 19
For finer horizontal adjustments,
loosen the PIR horizontal fine locking
screw on PCB.
Step 21
Tighten horizontal fine locking screw
on PCB.
NOTE:  Fine adjustment allows for small
changes (3 degrees right or left) between
coarse settings.
Step 20
Rotate horizontal fine adjust knob to
the desired position.
30 cm (12”) minimum
TROUBLE (NC)
30 VDC, 25 mA
TAMPER (NC)
30 VDC, 25 mA
ALARM OUTPUTS
(NO, NC, COM)
25 VDC, 125 mA,
Form C relay
END-OF-LINE
Connect terminating
resistors on last unit
POWER
10 - 15 VDC
50 mA (max) at 12 VDC
DT-901
DT-907
MODEL
RANGE
Switch S4
MIRROR
Selector
*Factory default setting.
Step 4
Set switch S4 to establish microwave
range.
Step 22
Tighten horizontal locking screw in
sensor support base.
Step 23
Remove jumper at J5, on the PCB,
to disable the LEDs after walk-
testing.
Step 24
Complete installation by closing top
cover and replacing bottom cover.
Wait 90 seconds for power-up self-
test to run.  All LEDs will flash.
.
 
NOTE:  LEDs flashing after 90 sec. = defective
PIR
(Green)
MW
(Yellow)
ALARM
(Red)
NOTE:  Fine adjust may be needed during
walk-test. See Supplemental Information.
2 m (6’)
4 m (12’)
DT-901
15 m (50’) CLOSED
50’
DT-907
61 m (200’) OPEN*
200’ *
DT-907
37 m (120’) CLOSED
120’
DT-901
27 m (90’)
OPEN*
90’ *
Step 18
Walk-test the sensor to check for
adequate detection coverage and to
verify the sensor is fully functional.
Two to four normal steps should
make the LEDs light and trigger an
alarm.
NOTE:  When there is no motion in the
detection area, all three LEDs should be off.
NOTE:  If an on-going self-test problem or an
INFORMER condition occurs, the LEDs
display a pattern that identifies the trouble.
See Supplemental Information (Table 3).
Step 17
Turn the microwave potentiometer
counterclockwise to decrease the
microwave range to minimum.
During walk-test, gradually turn the
potentiometer clockwise increasing
microwave sensitivity until the
desired range is obtained.
**Not recommended for DT-906
Optimal
Mounting
Height