  Select the mounting location.
  Wire the unit.
  Mount the unit.
a
  Walk-test the sensor.
Mounting Location Guidelines
• 2.3 m (7’6”) mounting height
• Avoid direct or reflected sunlight
• Aim sensor away from windows or heating/
cooling devices
• Sensor must have a clear line-of-sight to
protected area
•  
Use a small screwdriver to unfasten the housing
latch. Gently pull apart the housings.
•  
Push outward on the PCB latch and lift the PCB
out of the housing.
•  
Slide the wire through the wire channel in the
back housing.
•  
Mount the back housing flat against a wall or in a
corner.
•  
Replace the PCB.
•  
Connect wires as shown using 0.3 - 1.0 mm
2
(18 to 22 gauge) wire size.  Observe proper
polarity.
•  
Set Switch 3 to select the appropriate fluorescent light
filter (see Dip Switch chart on the next page).
•  
Apply power to the unit. Initialization and mask
detection are complete when the LED stops flashing
slowly.
•  
Adjust the microwave range to minimum setting
(25%) by turning the range adjustment counterclock-
wise using a small screwdriver.
•  
Replace the front housing.
•  
Begin walking through the detection area.
-
  
The LED will turn red, indicating an alarm detection.
•  
Increase the microwave range as necessary.
•  
Repeat the items in step 5a until proper detection
range is obtained.
b
 
 Optional: Walk-test using Zone Finder
•  
Use a screwdriver to short the test pads.
•  
During the Zone Finder walk-test mode, the LED
turns:
-
  
green for one second for every PIR detection;
-
  
yellow for two seconds for every microwave
detection.
•  
Adjust the microwave range as necessary.
•  
Zone finder mode times out after ten minutes.
Corner
Mount
Wire  Channel
Wall Mount
75%
100%
25%
50%
D
T
-7550C  DU
AL 
TEC
®
 Motion Sensor Installation Instructions
V+
V-
NC
C
Alarm
125 mA
25 VDC
Power
40 mA
7.5-16 VDC
(For UL 8.0-16 VDC)
NO
T
T
Trouble
125 mA
25 VDC
Tamper
50 mA
24 VDC
TBL
TBL
EOL
Use the Zone Finder mode to identify the PIR and/or
microwave pattern. In Zone Finder mode the red LED
is disabled.
  Separate the sensor housings and
       remove the printed circuit board (PCB).
For improved anti-mask
performance  the  look-down
mirror is disabled. To enable
look-down remove the mask.