Park Air Systems Limited B6350 Manuale Utente

Pagina di 73
DC Input Connector
A 3-pole chassis plug for connecting the dc input supply.
Detailed instructions for connecting the dc supply are given
in the installation chapter of this handbook on page 27.
Fuse F1
Fuse F1 protects the dc input positive supply circuit. It is a Size 0 fuse rated at 15 amps. The PAE part
number of the fuse is: 29-01350201.
Chassis Stud Connection
The chassis stud is used to provide a common earth point between the transmitter and the associated
equipment rack, or the transmitter and the user's system earth. The stud must not be used as a safety
earth. 
Connection details are given on page 26.
Facilities Connector CN5
A 15-way D-type socket used primarily to connect remote signals when the transmitter operates in AM
mode and does not form part of a MARC (or similar) system. The pin-out of this connector is given in
table 1-3 on page 17.
Apart from allowing connection of remote signals, this connector
makes some auxiliary signals available to the user. For example, a
24 volt (nominal) unregulated output supply. The auxiliary signals
can be employed by the user as and when required irrespective of
the operating mode.
Facilities connector CN5 as seen when looking at the rear panel.
Connections should be made using a 15-way D-type plug PAE part
number: 20-01150100 (plug), and 20-09150101 (cover). These are
supplied with the transmitter as item 3 (see page 22).
T6T General Information
Section 1
Page 15
Fig. 1-5. DC Connector
(DEV083-06)
Fig. 1-6. Facilities Connector
CN5 Pin-Out