Park Air Systems Limited B6350 Manuale Utente

Pagina di 73
Table 2-5 Signal Polarities
Signal
Description
State when Polarity is
set to NEG
State when Polarity is
set to POS
PTT output
This output, when active,
indicates the transmitter is
keyed. It is a grounding
output.
Output is a high
impedance when the
transmitter is keyed, and
0 volt when not keyed.
Output is 0 volt when the
transmitter is keyed, and a
high impedance when not
keyed.
Transmitter
inhibit
This input signal, when
active, prevents the radio
from being keyed. This is
a TTL input pulled-up to
5 V.
A 5 volt input inhibits the
transmitter.
A 0 volt input inhibits the
transmitter.
BIT initiate
An
input
signal
that
initiates a BIT interruptive
test. This is a TTL input
pulled-up to 5 V. The input
signal must be active for a
minimum of 300 ms; the
signal
cannot
then
be
activated again for at least
3 seconds.
A 5 volt input initiates a
BIT test.
A 0 volt input initiates a
BIT test.
Ready output
This output is active when
the
radio
is
ready
to
transmit
and
no
faults
have been detected by the
BIT circuitry. It is an open
collector output.
Output is a high
impedance when the
transmitter is ‘ready’, and
0 volt when not ‘ready’.
Output is 0 volt when the
transmitter is ‘ready’, and
a high impedance when
not ‘ready’.
Antenna
change-over
An output signal that can be used to control an antenna change-over relay when the
transmitter is used in conjunction with a T6R receiver. Antenna change-over is a
grounding output.
This signal cannot be independently set. It is always the same polarity as the PTT
output signal.
10. To exit the General Transmitter Settings Procedure, turn the switch to highlight Exit, then press
the switch. You are returned to the Main screen. When this procedure is complete, go to Setting
the Operating procedure starting on the next page.
T6T AM-Voice Operation
Section 2