Tait Limited TBA8K2 Manuale Utente

Pagina di 46
44
Power Management Unit Specifications
TB8100 Specifications Manual
© Tait Electronics Limited October 2004
General
Efficiency at Rated Output
Input-to-output Isolation
Control
86%
1000VAC, 50Hz, 1 minute
shutdown signal (isolated)
Optional Standby Output - DC Module (Continued)
Optional Auxiliary Power Supply
The output from this optional power supply PCB may also be used to trickle-charge a 12V, 24V or 48V battery.
DC Input Voltage
28V ±15%
DC Output*
Voltage
Current
Regulation
Ripple and Noise**
Ripple and Noise rms
Zero Load Ripple
*also for trickle-charging 12V, 24V or 48V battery
**100MHz bandwidth
12V
13.65V
3A maximum
±2%
50mV pp
10mV rms
100mVpp
24V
27.3V
1.5A maximum
±2%
50mV pp
10mV rms
100mVpp
48V
54.6V
750mA maximum
±2%
50mV pp
10mV rms
100mVpp
Protection
Overload/Short Circuit
Overvoltage
12V
electronic
current limit 
16V Zener diode
24V
electronic
current limit 
32V Zener diode
48V
electronic
current limit 
62V Zener diode
General
Efficiency at Rated Output
Input-to-output Isolation
Output-to-chassis Isolation
88%
1000VAC, 50Hz, 1 minute
500VAC, 50Hz, 1 minute
Connections
The following specifications refer to the external wiring and connectors which are connected to the PMU.  
They do not refer to the wiring and connectors built into the PMU itself.
AC Input
Connector Type
Current Rating
IEC female
8A