Honeywell International Inc. 7722TX Manuale Utente

Pagina di 2
Wireless Zone Sensor
Model 
7722TX
 
 No. X13790126060)
 
INTRODUCTION
This wireless 
 sensor is designed for use in a
temperature control system, operating 
in conjunction with a
centrally located Spread Spectrum Receiver (Model 7712RX).
Zone sensors are installed in areas where temperature
control is to be maintained. Ideally, the receiver should be
equidistant from all its assigned zone sensors.
The zone sensor measures temperature and periodically
transmits that information via RF 
 to its assigned
receiver. The sensor also transmits occupant set point
temperature. Other information that can be transmitted
includes special service requests, unique serial number of
sensor, and status of the batteries in the unit.
RF signals from wireless zone sensors are received by a
receiver, which will then send appropriate messages via
communication wires to specific 
 and air conditioning
equipment assigned to it. This information is also sent to a
central controller for system monitoring.
After mounting each wireless sensor, the Model 
Installation Tool can be used to assign each sensor to a
necessary instructions for this are contained  in the
instructions accompanying the 7712lT Installation Tool.
INSTALLATION
Location
Wireless sensors can be installed anywhere on common
walls and panitions. Operation will not be affected by metal
framing in walls or partitions; however, mounting to solid
metal walls or cabinets may reduce the operating distance
between the zone sensor and the receiver. Typical 
sight transmission range indoors for sensors is approximately
Mounting (Fig. 2)
A mounting plate is provided with the sensor. If attached to
the back of the sensor, release it by depressing the ‘locking
tab’ at the bottom center of the mounting plate with the blade
of a screwdriver, and then sliding the plate downward.
Mount the plate on the selected wall or partition with the
VELCRO strips or screws provided. Hooks must point upward
(the plate also has the word ‘TOP’ molded  into the top side).
Position the sensor onto the mounting plate so that the
mounting plate hooks enter the keyhole slots in the back of
the sensor, then slide downward to lock the sensor in place.
Battery Installation (Fig. 3)
The sensor uses two 
 Lithium batteries (supplied).
Remove the sensor cover by squeezing the cover at the top
and bottom and then pulling the cover away.
Install one battery in each compartment in the sensor. THE
S E N S O R   W I L L  N O T   O P E R A T E  
 ONLY ONE
Note: Batteries will not seat properly in their compartments if
installed incorrectly with regard to polarity. Make sure each
battery is fully seated in the compartment and that proper
 is being made at each end of the battery.
n
Figure   
 Wireless 
LCCANG TAB
 2. Mounting Plate
GREEN 
 
 
 
OF 
 TOOL)
LOCKING TAB 
 
TO RELEASE SENSOR FROM 
 3. Wireless 
 Cover Removed
Removing A Sensor From Its Mounting Plate
To remove a sensor from its mounting plate after installation,
press inward on the ‘locking tab’ at the bottom center 
 to
the left of the 
 header), and slide the sensor up and 
the mounting plate. See Figure 3 for 
 of the locking
tab.