ademco 8DL5800RR Manuale Utente

Pagina di 2
5877
  
Relay Receiver  / 
Relay Receiver / Relay Receiver / Relay Receiver
 
Installation Instructions / 
Instructions de montage (FRC) / Installation Instructions(LAES) / Installation Instructions (LAPT)
 
 
INTRODUCTION 
/ INTRODUCTION / INTRODUCTION / INTRODUCTION
 
The 5877 wireless relay module allows control of non-security system devices from compatible 5800 series wireless keys.  The module also includes an LED that can provide panel 
system status information. 
The 5877 wireless relay module allows control of non-security system devices from compatible 5800 series wireless keys.  The module also includes an LED that can provide panel 
system status information. 
The 5877 wireless relay module allows control of non-security system devices from compatible 5800 series wireless keys.  The module also includes an LED that can provide panel 
system status information. 
The 5877 wireless relay module allows control of non-security system devices from compatible 5800 series wireless keys.  The module also includes an LED that can provide panel 
system status information.
 
OPEN  
OPEN – FR-C 
OPEN – LA-ES 
OPEN – LA-PT 
 
5877-OPEN-V0
1
2
3
 
MOUNT 
MOUNT – FR-C 
MOUNT – LA-ES 
MOUNT – LA-PT 
 
•  Use the double-sided tape (supplied) to mount the 
sensor. 
•  Optional screws (supplied) are recommended.  
 
 
•  Use the double-sided tape (supplied) to mount the 
sensor. 
•  Optional screws (supplied) are recommended.  
 
•  Use the double-sided tape (supplied) to mount the 
sensor. 
•  Optional screws (supplied) are recommended.  
 
•  Use the double-sided tape (supplied) to mount the 
sensor. 
•  Optional screws (supplied) are recommended.  
 
 
 
NOTE:  Mounting screws must be used in installations where temperatures drop to freezing 32° F (0° C). 
NOTE:  Mounting screws must be used in installations where temperatures drop to freezing 32° F (0° C). 
NOTE:  Mounting screws must be used in installations where temperatures drop to freezing 32° F (0° C). 
NOTE:  Mounting screws must be used in installations where temperatures drop to freezing 32° F (0° C). 
 
 
PLUG IN 12VDC TRANSFORMER 
PLUG IN 12VDC TRANSFORMER – FR-C 
PLUG IN 12VDC TRANSFORMER – LA-ES 
PLUG IN 12VDC TRANSFORMER – LA-PT 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SPECIFICATIONS 
SPECIFICATIONS – FR-C 
SPECIFICATIONS -  LA-ES 
SPECIFICATIONS –LS-PT 
Electrical:  
12VDC Power Supply;  Operating Current 29-
31mA 
/
 
Electrical:  
12VDC Power Supply;  Operating Current 29-
31mA / 
Electrical:  
12VDC Power Supply;  Operating Current 29-
31mA / 
Electrical:  
12VDC Power Supply;  Operating Current 29-
31mA / 
Environmental Conditions:  
14° to 122° F (-10° to 50° C);  
< 90% RH (non-condensing) 
Environmental Conditions:  
14° to 122° F (-10° to 50° C);  
< 90% RH (non-condensing) 
Environmental Conditions:  
14° to 122° F (-10° to 50° C);  
< 90% RH (non-condensing) 
Environmental Conditions:  
14° to 122° F (-10° to 50° C); 
< 90% RH (non-condensing) 
Frequency:  
345 MHz 
Frequency:  
345 MHz 
Frequency:  
345 MHz 
Frequency:  
345 MHz 
Dimensions:  
4.5” H x 2.75” W x 0.25” D; (114.3mm x 
69.85mm x 6.351mm) 
Dimensions:  
4.5” H x 2.75” W x 0.25” D; (114.3mm x 
69.85mm x 6.351mm) 
Dimensions:  
4.5” H x 2.75” W x 0.25” D; (114.3mm x 
69.85mm x 6.351mm) 
Dimensions:  
4.5” H x 2.75” W x 0.25” D; (114.3mm x 
69.85mm x 6.351mm) 
Compatibility:  
Honeywell LYNX Series Controls, 5883H, 
6160RF and 6150RF Keypads produced 
after March 2007 (P/NSA6150RFAS-T3 
Printed Circuit Board).  5800 series 
Encrypted remotes not supported. 
Compatibility:  
Honeywell LYNX Series Controls, 5883H, 
6160RF and 6150RF Keypads produced 
after March 2007 (P/NSA6150RFAS-T3 
Printed Circuit Board). 5800 series 
Encrypted remotes not supported. 
Compatibility:  
Honeywell LYNX Series Controls, 5883H, 
6160RF and 6150RF Keypads produced 
after March 2007 (P/NSA6150RFAS-T3 
Printed Circuit Board). ). 5800 series 
Encrypted remotes not supported. 
Compatibility:  
Honeywell LYNX Series Controls, 5883H, 
6160RF and 6150RF Keypads produced 
after March 2007 (P/NSA6150RFAS-T3 
Printed Circuit Board). ). 5800 series 
Encrypted remotes not supported. 
 
 
 
 
 
APPROVALS / LISTINGS 
•  FCC part 15, Class B verified  
•  IC, ICES-003, Class B verified  
 
COMPLIANCE NOTES  
Product must be tested at least once each year. 
Product must be tested at least once each year. 
Product must be tested at least once each year. 
Product must be tested at least once each year.
 
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS 
USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 
<FR-C> REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS 
DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 
<LA-ES> REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS 
DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 
<LA-PT> REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS 
DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 
5877-MOUNTING-V0
Mounting Screws 
Mounting Screws 
Mounting Screws 
Mounting Screws 
Double-sided Tape 
Double-sided Tape 
Double-sided Tape 
Double-sided Tape 
Mounting Surface
Mounting Surface
Mounting Surface 
Mounting Surface 
 
 
Relay Terminals
Relay Terminals
Relay Terminals
Relay Terminals
Mounting Holes (2)
Mounting Holes (2)
Mounting Holes (2)
Mounting Holes (2)
12 Vdc Power Supply Connector
12 Vdc Power Supply Connector
12 Vdc Power Supply Connector
12 Vdc Power Supply Connector
12 Vdc Power Supply Receptacle
12 Vdc Power Supply Receptacle
12 Vdc Power Supply Receptacle
12 Vdc Power Supply Receptacle
LED
LED
LED
LED
Program Button
Program Button
Program Button
Program Button
Jumper
Jumper
Jumper
Jumper
5877-PARTS-LBLD-V0
NO   NC  COM
 
 
 
1
 
2
 
3