Honeywell International Inc. 8DL5800STAT Manuale Utente

Pagina di 12
WIRELESS THERMOSTAT
3
69-1535
Fig. 4. T8665A key locations and descriptions.
Setting up T8665A to Send Signal 
to W8665A,E Receiver Module
The T8665A Thermostat must be set up to send signals 
to the W8665 Receiver Module. Use the W8665A 
Receiver for single-zone applications. Use the W8665E 
RF Zone™ Panel for up to three T8665A Thermostats for 
multizone applications.
Single Zone Applications (one T8665A/ 
one W8665A)
1.
Place the Zone 1 DIP switch on the W8665A 
Receiver to the On position.
NOTE:
Observe that the Zone 1 LED on the W8665 
flashes.
2.
Press the thermostat Fan key to the On position. 
The receiver accepts the message, stores identity 
and then stops flashing the Zone 1 LED. The ther-
mostat is now set up to send signals the W8665A 
Receiver.
NOTE:
The word On and a fan blade 
 appear in the 
thermostat display to indicate the thermostat is 
calling for the fan to turn on.
3.
Set the System and Fan keys to the desired loca-
tions. 
NOTE:
At any time, if you want to stop the thermostat 
from sending signals to the W8665 Receiver, 
simply turn the DIP switch to the Off position. 
Follow the instructions in steps above to set up 
the thermostat again to send signals to the 
W8665A Receiver.
Multizone Applications (Up to three T8665A/
one W8665E)
IMPORTANT
The thermostats must be set up one zone at a 
time to ensure a unique address is used for 
each zone.
1.
Place the Zone 1 DIP switch on the W8665E 
Receiver to the On position.
NOTE:
Observe that the Zone 1 LED on the W8665 
flashes.
2.
Press the thermostat Fan key to the On position. 
The Receiver accepts the message, stores the 
identity of that zone, and stops flashing the Zone 1 
LED. The thermostat is now set up to send signals 
to Zone 1 of the W8665E Receiver.
NOTE:
The word On and a fan blade 
 appear in the 
thermostat display to indicate the thermostat is 
calling for the fan to turn on.
3.
Set the System and Fan keys to the desired loca-
tions.
NOTE:
At any time, if you want to stop the thermostat 
from sending signals to the W8665 Receiver, 
simply turn the DIP switch to the Off position. 
Follow the instructions in steps above to set up 
the thermostat again to send signals to the 
W8665E Receiver.
4.
Repeat steps 1-3 for zones two and three.
5.
Attach the zone number stickers, included with the 
thermostat, onto the thermostat case on the inside 
of the thermostat cover. See Fig. 5.
Fig. 5. Zone stickers included with T8665A 
Thermostat.
M20166
Time
Set Program
System
Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return
Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
INCREASE TEMPERATURE 
SETTING OR SCROLL 
FORWARD THROUGH 
INSTALLER SETUP OPTIONS
DECREASE TEMPERATURE 
SETTING OR SCROLL 
BACKWARD THROUGH 
INSTALLER SETUP OPTIONS
DISPLAY INFORMATION
SUCH AS PRESENT 
SETTINGS 
RETURN TO 
NORMAL
OPERATIONS
ENTER 
INDEFINITE 
OR TIMED 
HOLD MODE
SET CURRENT 
DAY AND TIME
SET CURRENT OR
PROGRAM DAY
CHANGE BETWEEN 
DAYLIGHT SAVINGS 
AND STANDARD TIME
INCREASE TIME SETTING
OR SCROLL FORWARD 
THROUGH INSTALLER SETUP 
AND SYSTEM TEST
DECREASE TIME SETTING OR 
SCROLL BACKWARD THROUGH 
INSTALLER SETUP AND SYSTEM TEST
COPY ONE PROGRAMMED 
DAY TO ANOTHER DAY
SET WAKE TIMES 
AND SETPOINTS
CHANGE BETWEEN 
HEATING AND COOLING 
SETPOINTS 
SET LEAVE TIMES 
AND SETPOINTS
SET RETURN TIMES 
AND SETPOINTS
SET SLEEP TIMES 
AND SETPOINTS
SELECT SYSTEM 
OPERATION 
SELECT FAN 
OPERATION 
Place one label inside
each thermostat door.
Zone 1
Zone 2
Zone 3
M13426