INSTALLATION INSTRUCTIONS
69- 1534- 1
W8665A,E
 RF Receiver Module
APPLICATION
The W8665A,E RF Receiver Module (RM) provides 
24 Vac control of HVAC equipment when used with a 
T8665A Chronotherm® IV Wireless Programmable 
Thermostat. The W8665A can be used with 1H/1C 
single-zone conventional applications. The W8665E can 
be used with up to three zones when used with a 
Honeywell EMM-3 Electronic MiniZone© Panel or TZ-3 
TotalZone™ Panel. See Table 1.
INSTALLATION
CAUTION
Equipment Damage Hazard.
Do not mount W8665 inside HVAC equipment.
Mount only on wall.
1.
Mount the thermostats in each zone of the living 
space using the installation instructions provided 
with each thermostat.
2.
Mount the dampers in the ductwork using the 
installation instructions provided with each damper.
3.
Mount the W8665 RF Receiver Module near the 
HVAC equipment on a wall. See Fig. 1.
4.
Level the W8665 for appearance only.
Fig. 1. W8665 mounting location.
Table 1. W8665 Description.
Model
Application
Stages
Zones
Comments
W8665A
Conventional gas, oil or 
electric systems.
1H/1C
One
Use with T8665A Wireless 
Thermostat.
W8665E
Conventional gas, oil or 
electric systems.
1H/1C
Up to three
Use with T8665A Wireless 
Thermostats.
Use with EMM-3 Electronic 
MiniZone™ Panel
Single or multi-stage 
conventional or heat 
pump systems.
1H/1C or up to 
3H/2C
Use with T8665A Wireless 
Thermostats.
Use with TZ-3 TotalZone™ Zone 
Control Panel.
M20162
WATER 
HEATER
W8665
ELE
CT
RO
NIC
 AIR
 CL
EA
NE
R
RETURN
AIR
FURNACE 
OR BOILER
HIGH
 EFFICIENCY
AIR CLEANER