– 3 –
Operating the Buttons
To Activate a Function
To activate a programmed function on a button, press and
hold the button down until the yellow LED flashes; then
release it.
System Status Indications Table
LED
LED Condition
Speech
System Status
System Armed Away
Armed Away or Maximum
On Steady
System Armed Stay
Armed Stay or Instant
Fire Fire Zone (Faulted Zone)
Fire Alarm in progress
Alarm Alarm Zone (Faulted Zone)
Armed, Burglary Alarm in progress
Red
Flashing
Alarm Alarm Zone (Faulted Zone)
Alarm Memory
Green
On Steady
System Disarmed Ready To Arm
Disarmed, Ready to Arm
Yellow  (Right)
Flashing
Silent
Indicates RF transmission (Non encrypted)
Yellow (Left)
Flashing
Silent
Indicates RF transmission (encrypted)
In Enter House ID Mode
In Enable or Disable Encryption Mode
Red & Green
Alternately
Flashing
Silent
In Set Volume Level Mode
AC Loss
AC Loss Condition
Low Battery
Low Battery Condition
Green
Flashing
System Disarmed Not Ready To
Arm
System Not Ready, Zones Faulted
To Request System Status
Because the 5804BDV is a two-way device, users can check
the system status before arming or disarming their system. To
check system status, press and release any button
momentarily.  The yellow LED will flash after you release the
button.  After a second or two, the 5804BDV will display the
system status information using a combination of LED and
sounder activity (see the System Status Indications Table).  If
5804BDV does not receive system status information from the
panel for approximately 5 seconds, it will shut itself down.  It will
also shut itself down if there is no button activity within 5
seconds of receiving a status update.
WARNING!
This device may not receive the system status
properly if it operates within a few feet of the
5881 RF receiver.
Multiple Button Operations
WARNING!
The 5804BDV should not be used for 24-hour
silent alarm, as the unit itself is not silent.
The 5804BDV can generate the same responses as keypad
panic key pairs of [
] + [#] and [
] + [1] by depressing “A” + “C
and “B” + “D” button pairs, respectively.  You must depress the
button pair for at least 2 seconds for the 5804BDV to recognize
the button pair command.  These button pairs allow the user to
activate panic, fire, and medical alarms depending on control
panel programming.
 
 
 
 
 
Low-Battery Indication
When the unit goes into a low battery condition, the yellow
LED will not flash when a button is pressed.  Change both
batteries immediately. Refer to instructions in “To
Install/Replace Batteries” paragraph on first page.
Specifications
Physical:
Belt Clip:
4.1H x 2.2”W x 0.8”D
Transmitter:
3.9”H x 2.0”W x 0.69”D
Battery:
Maxell CR2430 or Duracell DL2430
FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
CONTROL WITH WHICH THIS DEVICE IS USED.
FCC STATEMENT
This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:  (1)
This device may not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
FCC ID: CFS8DL5804BDU