Honeywell International Inc. 8DL5805BDV-1 Manuale Utente

Pagina di 5
- 2 - 
To View the House ID  
1. Enter Programming mode as described in step 1 
(previous page).   
2. Depress 
the 
2 button to view. 
The unit displays the stored number as programmed on the 
previous page (step 4), then automatically exits 
Programming mode. 
Programming a House ID in the Control Panel 
•  On VISTA-40 control panels and above, use Device 
Programming mode to enable the RF receiver and enter 
the House ID number. 
•  On VIA-30 control panels and below, go to field ✶24 and 
enter the House ID number.  
Programming the Buttons 
Each 5805BDV is assigned a unique serial number during 
manufacture.  Each button on the unit also has a unique 
“loop” number that must be programmed into the control 
panel during installation. Assign each button to an 
individual zone number and program the Input Type as BR 
(Button Type RF) by entering 5 in the control panel’s Zone 
Programming mode. 
Then, input the serial number by one of the following 
methods:   
•  Transmit twice from the device by pressing one of the 
buttons when prompted for the serial number. 
•  Enter the serial number manually through the keypad.  
•  Enter the serial number through Compass downloader 
software as applicable.   
Be sure to include the loop number of each button during 
programming (see loop assignments on previous page). 
 
NOTE: Do not use the 5805BDV for 24-hour silent alarm, 
as the unit itself is not silent. 
Button 1 
If you choose not to use Button 1, you must do the 
following to avoid a  “CHECK” condition when the button is 
accidentally pressed: 
1. 
Assign this button to a zone. 
2.  After the serial number has been programmed, re-
enter Zone Programming for that zone. 
3. At 
the 
“Zone Type” prompt, enter 00 and press [
✶].   
a)  On VIA-30 control panels and below, the system 
will ask whether you want to permanently delete 
that zone.  Enter 0 (No).  This will cause the 
system to retain the serial number, but render the 
button inactive.   
b)  On VISTA-40 control panels and above, continue to 
press [
✶] until you see the “Enter Zone No?” 
prompt again.  At this point, Press 00 and [
✶]. 
Then press 
99 to exit Program mode.  
On VISTA-40 control panels and above 
If a button is assigned to zone type 20 (Arm Stay), 21 (Arm 
Away), or 22 (Disarm), you must assign a user to the button 
in order for it to operate. Proceed with the following steps. 
To assign a user number to an Arm/Disarm button: 
1.  Enter [4-digit User Code] + 8 + [User No.] + [4-digit new 
User Code]. 
2.  Answer Yes or No to the “Open/Close Report?” question. 
3.  Answer Yes to the “RF Button?” question. 
4.  Enter the zone number assigned to the Arm/Disarm 
button. The keypad will show the summary of user 
information on its display. 
5.  Test the Arm/Disarm button to make sure it operates 
correctly. 
Activating High-Security Mode  
In order to activate the 5805BDV wireless key in High-
Security mode, you must use an encryption-capable 5800 
Series receiver or transceiver. 
 
1.  Program the 5805BDV in Zone Programming mode as 
usual. 
2.  After programming the unit, exit Zone Programming 
mode. 
3.  Enter Go/No Go Test mode at the control panel (see the 
control panel Installation Instructions for specific 
information.) 
4.  Press and hold the ON,  1, and 2 buttons at the same 
time. 
You will get an audio announcement stating 
Encrypted Mode On”
 with the LED flashing red and 
green alternately. 
5.  The 5805BDV transmits a special signal to the receiver. 
After 2 seconds, the unit will shut down. The 5805BDV is 
now in High-Security mode. 
 
Deactivating High-Security Mode 
Press and hold down the OFF1, and 2  buttons at the same 
time. You will get an audio announcement stating 
Encrypted Mode Off” with the LED flashing red and green 
alternately. After 2 seconds the 5805BDV will shut down and 
is no longer in High-Security mode.  
Adjusting Volume Level  
This unit is shipped with the volume set to the lowest level. 
To adjust the volume, proceed as follows:  
1.  Enter the Volume Level Programming mode by pressing 
and holding down the ON,  OFF, and 2  buttons 
simultaneously until the LED flashes red.  
 
NOTE: If no button is pressed for 5 seconds, the unit will 
automatically shut down and no change to the volume level is 
made. 
a. Press 
the 
1 button for low volume level, or 
b. Press 
the 
ON button for medium volume level, or 
c. Press 
the 
OFF button for maximum volume level.  
The word “CHECK” will be heard for the volume level 
adjustment. 
2.  Press the 2 button to accept volume setting. 
 
 
Volume level setting affects the life of the battery.  
Use low volume for maximum battery life.