Honeywell International Inc. 8DL5806-2 Manuale Utente

Pagina di 4
 
 
 
LIMITED WARRANTY 
 
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165 
Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans 
and specifications and to be free from defects in materials and workmanship under normal use and 
service for 24 months from the date stamp control on the product(s) or, for product(s) not having a 
manufacturer’s date stamp, for 12 months from date of original purchase unless the installation 
instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's 
obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any 
product(s) which is proved not in compliance with Seller's specifications or proves defective in materials 
or workmanship under normal use and service. Seller shall have no obligation under this Limited 
Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other 
than Honeywell factory service. For warranty service, return product(s) transportation prepaid, to 
Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791. 
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS 
FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION 
ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY 
CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER 
WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, 
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. 
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the 
product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that 
the product(s) will in all cases provide adequate warning or protection. Customer understands that a 
properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or 
other events occurring without providing an alarm, but it is not insurance or a guarantee that such will 
not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, 
SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR 
OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. 
HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS 
OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF 
CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE 
PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE 
REMEDY AGAINST SELLER. 
This warranty replaces any previous warranties and is the only warranty made by Seller on this 
product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is 
authorized. 
 
FCC STATEMENT 
FCC ID: CFS8DL5806-2 
This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) This device may not cause harmful 
interference (2) This device must accept any interference received, 
including interference that may cause undesired operation. 
IC: 573F-58062 
 
 
 
 
165 Eileen Way, Syosset, New York 11791
Copyright © 2004 Honeywell International Inc.
www.honeywell.com/security
 
ÊN6353V5mŠ 
N6353V5  7/04  Rev A 
 
N6353V5  7/04  Rev A 
 
ADEMCO 5806
 
Smoke Detector With Built-In  
Wireless Transmitter
 
 
INSTALLATION INSTRUCTIONS
 
General Information 
The ADEMCO 5806 Photoelectric Smoke 
Detector/Transmitter is intended for use with 
wireless alarm systems that support 5800 
Series devices, and contains a built-in 
transmitter that can send alarm, supervisory 
and battery condition messages to the 
system's receiver/control unit. Refer to the 
wireless system's instructions for the 
maximum number of transmitters that can be 
supported. 
Alarms:  The smoke detector is powered by 
two 9-volt batteries and will sound its built-in 
horn when smoke reaches the detector (the 
LED indicator will also flash rapidly). A 
message will also be sent to the wireless 
control and the smoke detector's ID number 
will be displayed at the keypad.  The alarm 
message will be transmitted every 4 seconds, 
until the smoke condition has cleared and the 
detector has reset.  About 1 second after the 
horn has stopped, a Restore message will be 
transmitted to the control and it will then be 
possible to clear the ID number from the 
display. During normal or low battery 
conditions, the LED indicator will flash about 
once every 40 seconds. 
Low Battery: The detector indicates a low-
battery condition by emitting a "chirp" about 
once every 40 seconds. A low-battery 
message will be sent to the control unit upon 
any transmission following the first battery
 
 
 
chirp (with the detector's ID number displayed 
at the keypad). The battery should be replaced 
within 30 days following the low-battery 
signals. 
False Alarm Protection: In order to reduce 
the possibility of false alarms due to cigarette 
smoke, dust, steam, insects, etc., the detector 
will not transmit an alarm signal until its horn 
has sounded continuously for about 6 
seconds. A delay also occurs when the 
detector is tested. Therefore, the test button 
must be held down for about 20 seconds 
before the horn will sound. The first alarm 
signal will be transmitted within 6 seconds after 
the horn sounds.  
Programming:  Note that the control system 
must “enroll” the smoke detector’s ID during 
installation of the system. The control should 
be programmed to “enroll” the 5806 as an “RF” 
type unit (i.e., supervised RF).  See the 
PROGRAMMING section in this instruction 
book and the control unit’s Installation 
Instructions for further details. 
Tamper Protection: The detector has 
provision for a tamper function if desired. 
When the tamper function, is enabled, the 
detector will cause a CHECK to be displayed if 
it is removed from its installed location. See 
TAMPER PROTECTION for detailed 
instructions. 
Battery Installation and 
Replacement 
 
TO REMOVE
TO SECURE
INDICATOR LIGHT.
FLASHES ONCE
EVERY 40 SECS
DURING NORMAL
OPERATION
TEST BUTTON
SENSING 
CHAMBER
OPENINGS
 
The 5806 is equipped with two 9-volt batteries, 
which can double the time between battery 
replacement (compared to a single 9-volt 
alkaline battery). Refer to the 
SPECIFICATIONS section for acceptable 
batteries. The batteries should be changed 
within 30 days following the low battery beeps 
(about once every 40 seconds).  There will 
also be a low-battery display on the system’s 
keypad. Be sure to replace BOTH batteries 
with fresh ones. 
Important: Do not mix battery types.