GENERAL INFORMATION  
The 5815 is a two-zone Door/Window Transmitter that has its own unique serial number. The control unit is required to "enroll" the serial 
number prior to its usage in the alarm system. Refer to the control unit's installation instructions for further details. Note: During 
programming of the control unit, 5815 transmitters should be treated as "RF" (i.e., supervised RF) Type (mandatory for UL installations).  
The 5815 provides two input loops (zones): the firstfor a wired closed-circuit contact loop, and the second for its built-in reed switch (used in 
conjunction with a magnet, as described below). One or both inputs may be used. For UL installations, a contact may not be more than 3 
feet from the transmitter.  
The 5815 includes a built-in cover tamper, which is activated when the cover is removed. 
 
MOUNTING  
For proper orientation of the unit in relation to the mounting plate, loop wiring, and/or magnet, read all of this section before installing the 
unit.  
The description that follows assumes that the unit will be mounted as shown in the diagrams, with the magnet (if used) located in one of the 
positions shown in Figure 2. The unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting plate 
and (if used) magnet is maintained.  
Although the unit can be mounted directly to a surface, we recommend that the mounting plate be used, for ease in removing the unit for 
servicing should it become necessary.  
Before mounting the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength and 
reorient or relocate the transmitter if necessary.  
1. Remove the transmitter's top cover 
by inserting the flat blade of a small screwdriver into the pry-off slot at one end of the unit 
(see Fig. 1 for location), and slightly twisting the blade until the cover disengages.    
     Figure 2. 5815 (shown without cover)  
1. 
2. Disengage the attached mounting plate from the case by inserting the blade of a small screwdriver into the locking tab 
release window (see Figure 1) and pressing it against the locking tab (also shown in Figure 1), while sliding the mounting plate upward 
along the case back until free.  
 
3. Install  the mounting plate, with its two case-holding posts pointing up (in this example), in the location selected as 
described in the control panel's installation instructions. Use the flat-head screws supplied.  
 
Note: If a wired contact loop is to be used, with concealed wiring, the wire exit hole in the wall must be located under the wire 
entry hole in the case as shown in Figure 2, and no more than 1/4" in diameter.  
2. 
4. If 
 a wired contact loop is to be used, feed concealed wiring through the slot in the case back, but do not connect to 
the terminal block yet. For surface wiring entry, two thin "breakout" areas are provided in the case wall (see Figure 1).   
3. 
5. Attach the case back to the mounting plate  
by sliding the keyhole slots in the case back down onto the mounting 
plate's case holding posts. The locking tab will click as the case back locks in place.  
4. 
6. If a reed switch is to be used, mount a No. 5899 Magnet (obtained separately) adjacent to the reed switch, or adjacent to 
the top of the case (see Figure 2). In either case, the magnet must be mounted within one-half inch of the reed switch.  
 
LOOP WIRING CONNECTIONS
 (If used) 
With the battery still not inserted, connect the contact  
loop wires to the unit's loop terminals (see Figure 2).  
 
Caution: Make sure that the bared sections of the loop wires do not short to the reed switch or antenna.