Honeywell International Inc. 8DL5817-1 Manuale Utente

Pagina di 2
 
— 2 —
 
— 3 —
 
3.  If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at 
one corner of the plate (surface wiring is mentioned in Step 5 below). 
4. Install the mounting plate, with its case holding posts pointing up (in this example), in the 
location selected as described in the control unit's installation instructions. Use the flat-head 
screws supplied.  
5. If concealed wiring is to be used, feed it through the slot in the case back but do not connect 
to the terminal block yet. Surface wiring should enter via the thin "breakout" area provided in 
the case wall. 
6.  Attach the case back to the mounting plate by sliding the keyhole slots in the case back down 
onto the mounting plate's hooks. The locking tab will click as the case back locks in place. 
7  Set the DIP switch (after the control has enrolled the transmitter's input IDs) for the desired 
primary loop characteristics, as described in the table below.   
 
P R I M A R Y   L O O P   O P T I O N S   T A B L E 
SWITCH 
 
D I P   S W I T C H   P O S I T I O N 
SETTING 1 
ON 
REPEATING 
TRANSMISSION  
(every 4 sec.)  
UPON PRIMARY  
LOOP FAULT 
Use for high-priority  
alarm, such as fire. 
NORMALLY  
OPEN CIRCUIT 
PRIMARY LOOP 
SLOW 
PRIMARY LOOP 
RESPONSE 
(Approx. 200mSec
Normally Closed 
Response Time) 
3 MINUTE, ALL LOOP 
TRANSMISSION INHIBIT 
AFTER RESTORE OF 
PRIMARY LOOP 
See Note c. 
This affects the Aux. loops as 
well.  Use on frequently used 
doors, etc. to conserve battery. 
OFF
 
SINGLE 
TRANSMISSION  
PER PRIMARY 
LOOP  
CHANGE-OF-
STATE 
NORMALLY  
CLOSED 
CIRCUIT 
PRIMARY 
LOOP 
FAST 
PRIMARY LOOP 
RESPONSE 
(Approx. 5mSec 
Normally Closed
Response Time) 
NO  
TRANSMISSION  
INHIBIT 
 
Notes:  a. While the transmitter is being enrolled by the control, all DIP switch positions should 
be OFF. 
 
b. Except in the case of the position 4 ON setting, the Auxiliary loops are not affected by 
the DIP switch settings. 
 c. 
For UL installations with fire zones, the position 4 ON setting must not be used. 
 
WIRING CONNECTIONS 
With the battery still not inserted, connect the loop wiring to the unit's terminals (see Diagram 2).  
Note:  If a contact loop is not to be used, no connection is needed across its terminals. 
 
BATTERY INSTALLATION/REPLACEMENT 
1. Remove the transmitter's cover (if not already off) as described in Mounting Step 1. 
2. Observe correct polarity and insert the battery provided into the battery holder (see 
Diagram 2). Take care not to bend the antenna. 
Note: Replace 
battery 
only with: Duracelll DL123A, Sanyo CR123A,  
Panasonic CR123A, ADEMCO 466, or Varta CR123A. 
CAUTION:  Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 
212°F (100°C), or incinerate. Dispose of used batteries promptly. Keep away 
from children. 
3.  To replace the cover, engage the hooks along one edge and snap shut. 
 
SPECIFICATIONS 
Dimensions 
1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm) 
Battery 
3V Lithium (see BATTERY INSTALLATION/REPLACEMENT). 
 
 
 
 
CASE
HOLDING
POSTS (2)
PLATE
MOUNTING
HOLES (2)
ALIGNMENT GUIDE STRIP
(NOT USED IN THIS APPLICATION.
BREAK AWAY, IF DESIRED.)
CONCEALED WIRING
ENTRY HOLE
CASE LOCKING TAB
 
 
Diagram 1: MOUNTING PLATE 
 
 
 
 
Diagram 2: 5817 (SHOWN WITH COVER REMOVED)