ademco 8DL58241 Manuale Utente

Pagina di 2
 
5834-4 Series
Wireless Key Transmitter
INSTALLATION AND SETUP GUIDE 
 
 GENERAL INFORMATION 
The 5834-4/5834-4EN key transmitters are portable wireless transmitters for use only with wireless alarm systems that support 5800 Series 
receivers (ex. VISTA series, LYNX PLUS, LYNX Touch). The 5834-4EN is identical to the 5834-4 except the 5834-4EN has a plated bezel 
and key ring. References to the 5834-4 throughout this document refer to both models. 
•  Buttons are typically used for arming and disarming, but can be 
programmed for any appropriate zone response. 
•  A button must be pressed and held until the LED begins to flash 
to activate a button function. This press and hold feature 
minimizes the possibility of accidental transmissions. 
•  The factory-installed replaceable lithium battery provides power 
for up to five (5) years. 
•  The 5834-4 transmitter provides up to eight (8) functions and has 
an optional high security (encrypted) mode that sends rolling-
code encrypted messaging to the RF receiver.  
 
High Security Mode Note: If used in high security mode, must 
be used with a receiver or control that supports high security 
mode. i.e., 5881EN, 5883, 6150RF, or 6160RF receiver or 
LYNXR Series control panel (Rev 13.1 or higher). 
PROGRAMMING 
For complete details on how to program the transmitter at the control panel, see the control unit's Installation Instructions. When 
programming, note the following: 
•  Each 5834-4 transmitter has two unique serial numbers assigned during 
manufacture.  
•  Each button on the unit also has a distinct "loop" number (refer to the 
Loop Number diagram at right) that you must program into the control 
panel during installation. 
•  Assign each button to an individual zone and designate the Input Type 
as "BR" (Button Type). 
•  When prompted for the serial number, press and release the 
appropriate button(s) twice, or, manually enter the serial number at the 
keypad.  
 
NOTE: Serial #2 is one (1) digit higher than serial #1, which is printed 
on the rear of the transmitter.  
USING HIGH SECURITY MODE IN COMPATIBLE RECEIVERS 
AND LOCALLY IN AN RF KEYPAD (eg., 6150RF) 
 
If used with LYNXR Series controls earlier than Revision 
13.1, Standard Mode must be selected. 
First select High Security mode, then activate it. Activation syncs the key 
fob with the security system. 
1.  Select High Security mode: 
 
Mode 
Simultaneously hold down for 5 secs… 
High-Security  
A - C - D (LED flashes Red when transmitting) 
Standard  
B - C - D (LED flashes Green when transmitting) 
2. Activate High Security mode:  
•  if the key fob is enrolled into the panel, put the security system into 
Go/No Go Mode 
•  if the key fob is enrolled locally into a 6150RF, go to Step 3 of 
6150RF “
Programming WITH Local Wireless Keys”, 
     then press the appropriate set of buttons as follows: 
Serial Number  Simultaneously hold down until beeps sound… 
A - B - C buttons (system beeps twice to confirm) 
A - B - D buttons (system beeps twice to confirm) 
 
 
Loop Numbers for the 5834-4 Buttons 
 
5834-008-V2
SERIAL #1
LOOP 4
SERIAL #1
LOOP 1
SERIAL #2
LOOP 1
SERIAL #2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #2
LOOP 4
SERIAL #1
LOOP 2
SERIAL #1 FUNCTIONS ACTIVATE WHEN THE RESPECTIVE
BUTTON IS HELD DOWN UNTIL THE LED FLASHES.
 
SERIAL #2 FUNCTIONS ACTIVATE WHEN THE TWO RESPECTIVE
SERIAL #2 BUTTONS ARE PRESSED AT THE SAME TIME AND
HELD DOWN UNTIL THE LED FLASHES.
NOTE
1.
2.
SERIAL #2
LOOP 2
A
C
B
D
 
 
Using a Button: To activate a programmed function, 
press and hold the appropriate key(s) until the LED 
begins to flash (about ½ second).
 
  
SIA INSTALLATIONS: Use only serial #2/loop 2 (C & D 
keys) for the panic function. Do not use serial #1/loop 1 (D) 
key. 
ASSIGNING A WIRELESS KEY TO A USER 
•  On most control panels, if the wireless key is assigned to arm and disarm the system, you must assign it to a user in order for it to 
operate. This is accomplished through User Code programming at the control panel. See the control panel’s Installation and Setup 
Guide for specific instructions on programming User Codes.  
 
The table below summarizes the procedures. 
•  If programming arming and disarming functions on both serial numbers, each serial number must be assigned to a separate user.
 
 
On Vista 32/40/50/50P/100 and up 
You must assign a user to the button in order for it to operate. 
To assign a user number to the Arm/Disarm button: 
1.  Enter [4-digit User Code] + [8] + [User No.] + [new User Code]. 
2.  Answer Yes or No to the “Open/Close Report ?” question. 
3.  Answer Yes to the “RF Button ?” question. 
4.  Enter the zone number assigned to the button. 
5.  Keypad display shows summary of user information. 
6.  Test all functions for proper operation.
 
On Vista-20P/15P/10P/Vista-21iP and variants 
You must assign a user to the button in order for it to operate, and 
must enter a sequence of keystrokes as described below.  
NOTE: There is a two-second timeout for keystroke commands on 
Vista P series panels, therefore you must enter the keystrokes as 
quickly as possible. 
1.  Enter [4-digit Master Code] + [8] + [User Number] +  
[# 4] + [two digit zone number] assigned to the fob. 
2.  Test all functions for proper operation.
 
PLEASE SEE AGENCY 
INFO ON PAGE 2