Honeywell International Inc. 8DL5839US-1 Manuale Utente

Pagina di 4
®
 
N8610-1V1  7/03 
5839
 
Wireless Bidirectional Alpha Keypad
INSTALLATION AND SETUP GUIDE
 
GENERAL INFORMATION 
The 5839 is a wireless bidirectional alpha keypad that is 
used in conjunction with a 5883 transceiver. The 5839 should 
be used as an auxiliary keypad in addition to one or more 
wired keypads. It should not be used as the only or primary 
keypad. 
In non-addressable systems, the number of wireless keypads 
that can be used is unlimited. In addressable systems, refer 
to the table on the next page for limitations on the number 
of keypads that may be addressed for each family of security 
systems. For the following controls, the 5839 is compatible 
only with the revisions indicated:  
Control Panel
 
Compatible Revisions
 
Vista-15P 
WA15P-1.3 and higher 
Vista-20P 
WA20P-1.4 and higher 
FA148C 
WA15P-1.3 and higher 
FA168C 
WA20P-1.4 and higher 
NOTES:  
•  Up to eight (8) 5839s can be used on any one partition. 
•  Up to two (2) can be used on each of two partitions. 
•  The 5839 is not recommended for use on more than two 
 
(2) partitions of a multi-partition system 
The keypad is compatible with most controls and performs 
the same user functions as a wired alpha keypad.  
Activate the 5839 by pressing any key on its keypad, (unless 
powered by an external power-pack referred to in the 
POWER CONNECTIONS paragraph).  
 
The keypad returns to its inactive state if no keys are 
pressed for 30 seconds. After activation, pressing the [
✱] key 
displays the current status whenever desired. The 5839 
cannot
 be used to program a control panel (an alpha 
keypad hard-wired to the control is required). 
MOUNTING 
The 5839 is designed to be wall mounted, mated to its 
mounting plate. The mounting plate secures the keypad to 
the wall and holds the battery in place.  It is necessary to 
keep the mounting plate attached to the keypad at all times. 
Before mounting the 5839 permanently, determine a good 
RF location by first conducting a Go/No GO test from the 
panel. Refer to the Go/No GO test mode in the Installation 
and Setup Guide for the panel.  
Avoid mounting locations on or near large metal objects, 
since these can decrease the transmission range or block 
transmissions. 
BATTERY INSTALLATION OR REPLACEMENT 
Separate the keypad from its mounting plate by sliding the 
keypad up and away from the mounting plate.  
Install or replace the 9 Volt Ultralife Lithium battery (No. 
465) in the battery compartment provided at the rear of the 
keypad. Ensure that battery female (-) and male (+) 
terminals are properly oriented with the battery spring clip 
connections.  
Reattach the keypad to its mounting plate by aligning the 
four mounting holes in the keypad case back with the four 
mounting clips on the mounting plate. Lower the keypad 
onto the clips.  
Anticipated battery life is 1.5 years. 
 
PROGRAMMING 
Before enrolling the 5839, you must first be sure that a 
wireless transmitter is already enrolled in a zone OR that a 
House ID has been programmed into the panel. 
 
5839-002-V0
PANIC
READY
INSTANT
CODE
CHIME
MAX
TEST
BYPASS
OFF
AWAY
STAY
4
5
6
7
8
*
0
#
1
2
3
SHOWN WITH FLIP-DOWN
KEY COVER REMOVED
9
* * * *
DISARMED
READY TO  ARM
* * * *
FIRST PRESS ANY KEY,
THEN PRESS AND HOLD
TO ENTER PROG. MODE 
 
 
To enroll the 5839, program special keys, and enable sounds, 
perform the following steps: 
1.  Place the control panel in Go/No-Go test mode. Wait at 
least 30 seconds before enrolling and programming the 
5839 keypad and its associated 5883 transceiver. 
 
NOTE:
 It is recommended that you enroll the 5839 only 
from its final mounting position to ensure proper signal 
strength. Performing step 1 is only necessary when first 
enrolling the 5839. To modify only the Keys or Sounds 
options, it is not necessary. 
 
 
2. a. Enter 5839 program mode by first pressing any key to 
activate the keypad, if necessary. 
  b. The prompt at right is 
displayed:
 
Waiting for mesg  
 
  c. Press and hold down keys [1] and [3] at the same time 
for several seconds until all 2 x 16 character locations 
on the LCD indicate solid black rectangles. This tests 
all the elements of the LCD display.
 
3. 
After all display elements are 
tested, the Options? prompt at 
right appears: 
5839 Rev.n.n.US  
Options? 
✱=Y #=N 
Where: 5839 Rev.n.n. = Keypad software revision level
 
US = Indicates this keypad is intended for use in the US
 
 = Press to advance to next prompt.
 
# = Press to exit from program mode.
 
4.  a. The Setup? prompt at right 
appears after selecting “Y” from 
the previous prompt. 
Setup?               
✱ = Y   # = N