Refer to Supplemental Information (next page) for complete descriptions of these installation steps 
 
 
5-051-735-00G 
Page 1
 
 
 
FlexGuard
®
 
5853 Wireless Glassbreak Detector Installation Instructions
 
5853 Glassbreak Detector Internal Parts 
 
CR-123A
CR-123A
Mounting Hole
Mounting Hole
Batteries
Front Tamper Switch
LED Indicators
Microphone
Sensitivity Switches
Wall Tamper (behind battery)
Test Mode pads (on PCB)
Front Cover
Latch
Break out flash
for cover screw
2
1
ON
OFF
5853_001-v0
 
 
Connect Batteries 
Remove pull tab to connect batteries 
 
 
 
 
Select Mounting Location 
For the best detector performance, select a mounting 
location that is: 
  within 7.6 m (25 feet) of the protected glass; 
  within clear view of the protected glass; 
  at least 2 m (6.5 feet) from the floor; 
  at least 1 m (3.3 feet) from forced air ducts; 
  at least 1 m (3.3 feet) from sirens or bells greater 
  than 5 cm (2 inches) in diameter. 
  between the protected glass and any heavy 
window coverings that may be present. 
Alternatively, when heavy window coverings are 
present, the detector can be mounted on the frame 
of the window. 
Avoid mounting the detector on the same wall as the 
protected glass, on free-standing posts or pillars, or in 
rooms with noisy equipment (air compressors, bells, 
power tools, etc.), if this equipment is operated when 
the detector is armed. 
 
Wall Mount 
(Top View)
W
allMnt-001-V0
 
 
CeilingMnt-001-V0
Ceiling Mount: (Side View)
 
 
NOTE:  If the device is ceiling mounted, the end with the 
hole (Microphone end) should face the protected glass. 
 
 
Set Sensitivity (Range) 
 
SENS2
SENS1
CR-123A
CR-123A
SENS2
SENS1
5853_004-v0
ON
OFF
 
 
 
SENS1 & SENS2 configure sensitivity 
SENSITIVITY APPROXIMATE 
RANGE  
SENS1 SENS2 
MAX 7.6m 
(25 
ft) 
OFF OFF 
MEDIUM 4.6m 
(15 
ft) ON OFF 
LOW 
3m (10 ft) 
OFF ON 
LOWEST 1.5m 
(5 
ft) ON ON 
 
NOTE:  Ranges are approximate and vary with each 
room’s acoustic properties.  Always verify range with a  
FlexGuard FG-701 Glassbreak Simulator. 
 
Enroll Detector 
Refer to text and control panel's installation 
instructions.   
When programming the transmitter, specify: 
  Input Type = 3 (Supervised RF) 
  Loop Number = 1 
 
Mount Detector
  
  Use mounting holes as a template to mark 
mounting locations on ceiling or wall. 
  If using the optional back tamper, remove the 
batteries, then mark the wall tamper location 
through its mounting hole. 
  Mount detector using appropriate hardware. 
NOTE:  A screw capture feature designed to 
make ceiling mounting easier will cause some 
resistance when inserting the screw into the 
plastic. 
  Close detector cover when finished. 
 
CR-123A
CR-123A
SENS2
SENS1
5853_003-v2
(Screw not supplied.)
3.5 mm x 38 mm
(#6 x 1-1/2")
3.5 mm x 38 mm
(#6 x 1-1/2")
#6 (3.5 mm) screw for 
Optional Rear Tamper
*3.5 mm (#6) 
screws works best
with the screw 
retention feature.
To work properly, the back tamper
screw must be screwed into  a 
framing stud or a heavy-duty
hollow-wall anchor, such as a 
#8 self-tapping anchor.  This type 
of back tamper is not suitable for 
use on acoustic ceiling tile. 
 
 
*The screw retention feature simplifies installation:  A 
rib in the screw cavity lightly holds the screw in place 
when installing the detector.  
 
Test Detector Installation 
Enter Test Mode using a FlexGuard FG-701 
Glassbreak Simulator (see Testing the Detector on the 
next page).  To enter Test Mode manually, short the 
Test Mode pads (as shown below). 
 
CR-123A
CR-123A
SENS2
SENS1
SENS2
SENS1
5853_005-v0
TEST
TEST
 
Install Cover Screw (optional) 
 
5853_006-V1
2.9 mm (#4) scre
w, 
6 mm (1/4-in.) long
 
 
 
 
 
 