Honeywell International Inc. 8DL5890-1 Manuale Utente

Pagina di 2
N5987V3  5/04  Rev. A 
ADEMCO 5890
 
PASSIVE INFRARED MOTION 
DETECTOR/TRANSMITTER
 
INSTALLATION AND SETUP GUIDE 
 
GENERAL INFORMATION 
The 5890 Passive Infrared Motion Detector/ 
Transmitter is a battery-operated wireless device 
intended for use as part of a 5800 Series wireless 
alarm system.  
Designed for use in commercial and residential 
installations, the 5890 is a wall-mounted unit with a 
standard lens that provides wide-angle protection 
up to a range of 40 feet (12m). For best coverage, 
mount the detector so that the likely direction of 
intruder motion is across the pattern.  
Two optional interchangeable lenses are available 
for this detector – the 199PA Pet Alley lens, and 
the 199LR Long Range lens (see 
PROTECTION 
PATTERNS FOR  OPTIONAL LENSES on last 
page).  
This document provides installation instructions for 
the 5890, but the installer must be familiar with the 
Installation Instructions for the 5800 Wireless 
Alarm System with which the 5890 is intended to 
be used. 
 
FEATURES 
•  Wireless operation for fast installation. 
• Dual-element pyro-electric sensor provides 
positive protection while minimizing false 
alarms. 
• Alternate-polarity pulse count option offers 
greater stability in adverse environments. 
•  Provision to turn LED on while Walk Testing 
(LED is turned off after testing). 
• Tampered cover – unit transmits message if 
cover is removed. 
•  Wall or corner mounting options. 
•  Optional Pet Alley and Long Range lenses 
available. 
 
SYSTEM DESCRIPTION 
Optical System: Uses efficiently designed Fresnel 
lenses. 
Radio Transmitter: The built-in transmitter serves 
only as the communication link to the alarm 
system's Receiver/Control, and can send alarm, 
tamper, supervisory, and battery status messages 
to the system's receiver/control. The transmitter is 
not used for detection purposes. Each detector has 
a unique ID code permanently assigned at the 
factory. This ID needs to be "enrolled" by the 
control system at the time of installation. This 
allows each detector used in the system to be 
uniquely identified. The control must be 
programmed to "enroll" the 5890 as an "RF" type 
unit (i.e., supervised RF).  
To conserve battery life during normal operation, 
no more than one transmission sequence will 
occur within a 3-minute period. There is no such 
time restriction in "test" mode. 
Alternate Polarity Pulse Count: Two jumper-
selectable detection response modes are provided: 
Instant response (Pulse Count OFF) and Alternate 
Polarity Pulse Count (Pulse Count ON). With Pulse 
Count OFF, any
  detected change in infrared 
energy will trigger an immediate alarm signal. This 
mode is recommended when the detector is used 
to monitor a narrow hallway where coverage is 
provided by only a single zone. 
Use the Pulse Count ON mode when the detector 
is installed in areas where periodic changes in 
infrared energy levels are normal (for example, 
where forced air heating ducts are present).  
In this mode, it requires at least two detected 
changes in infrared energy within a short period 
before an alarm will be triggered. 
Important Note: If the detector is to be used in the 
Pulse Count mode, be sure to Walk Test the unit in 
this mode. 
SPECIFICATIONS 
Coverage: 
Standard Lens:  40 ft x 56 ft (12m x 17m). 
 
  18 zones (9 long, 5 intermediate, 
  
short 
range). 
 
199LR Lens:  60 ft x 6 ft (18m x 1.8m).  
 
  5 zones (1 long, 2 intermediate,  
  
short 
range). 
 
199PA Lens: 40 ft x 60 ft (12m x 18m).  
  
12 
zones. 
Pulse Count: 
Installer-selectable On/Off link. 
Detectable  
Walk Rate: 
 0.5 
– 5ft/Sec (0.15 – 1.5m/Sec). 
Mtg. Height: 
7 ft nominal (2.1m) but may be 
mounted at other heights (see 
Table 1). 
Walk Test 
Indicator: 
Red LED with Test/Normal  
  
(disable) link. 
Batteries: 
Two 3-volt Lithium batteries.  Use 
only ADEMCO No. 466, Duracell 
DL123A, Panasonic CR123A, 
Sanyo CR123A, or Varta CR123A. 
0perating 
Temperature: 
32°F – 122°F (0°C – 50°C). 
Operating 
Humidity:
 
Up to 95% RH (max.), non-
 condensing. 
Dimensions: 
2-11/16"W x 5"H x 1-7/8"D 
(68mm x 127mm x 48mm). 
TOP VIEW
SIDE VIEW
90˚
90˚
0
10 ft
20 ft
30 ft
40 ft
(3m)
(6m)
(9m)
(12m)
7 ft
(2m)
 
Figure 1. 
Standard Wide-Angle Protection Pattern 
 
BATTERY INSTALLATION 
1.  Remove front cover by inserting a large 
screwdriver blade (or small coin) in groove 
between cover and base at the location shown 
in Figure 2; rotate blade to override snap fit, 
then lift cover off. 
2.  Observing correct polarity, install the two 
Lithium batteries (supplied)  into the battery
 
holders, as shown in Figure. 5. Make sure the 
batteries are firmly seated. 
3.  Replace the cover (snap fit). 
Battery Caution: 
Risk of fire, explosion, and burns. Do not recharge, 
disassemble, heat above 100°C, or incinerate. 
Dispose of used batteries promptly. Keep away 
from children. 
Programming Note: If the detector’s ID has not 
been programmed into the system (i.e., this is an 
initial detector installation), refer to the 
PROGRAMMING  section below and perform the 
ID “enrolling” procedure before mounting or 
testing the detector. 
 
PROGRAMMING 
You must “enroll” the detector’s ID during 
installation of the system. Program the 5890 as 
an “RF” type unit (i.e., supervised RF). 
  
To program the detector, place the LED jumper in 
the TEST position (see Figure 5), the Pulse Count 
jumper in the OFF position, batteries installed, and 
cover on. Temporarily cover the lens (a cloth will 
do) to prevent any activation by the detector.  
When prompted for the device’s serial number, you 
may either manually enter it or transmit from the 
unit (remove the cloth cover and motion your hand 
over the lens to activate the detector, press the 
tamper switch, etc.).  
Refer to the control panel 
installation instructions for programming details.  
 
Return LED jumper to the NORMAL position 
after it is enrolled in the control.
 
 
INSTALLATION 
Installation Hints 
• 
Do not install where the detector is exposed to 
direct sunlight or directly above strong sources 
of heat. 
• 
Make sure the detection area does not have 
obstructions (curtains, screens, large pieces of 
furniture, plants, etc.) that may block the pattern 
of coverage. 
• 
Avoid locating a unit in areas that contain 
objects likely to produce a rapid change in 
temperature, such as central heating, radiators, 
or ducts (or heaters of any kind), air 
conditioners, open flame, etc. 
  Do not mount on an unstable surface. 
Radio Transmission Path Check 
Verify that a strong transmission path between the 
5890 and the system's Receiver/Control exists 
before permanently mounting the detector.  Do 
this by performing the
 Walk Test  (described later) 
with the detector temporarily mounted in its 
proposed location.  The 5890 will transmit when 
sensing motion (when you wave an arm or walk 
into area). Sometimes, moving the detector only a 
few inches means the difference between a strong 
and weak transmission path. Experiment until you 
are satisfied that the location provides the 
strongest transmission path, while still being 
practical for the protection pattern desired.   
This test also verifies that the detector has been 
correctly programmed into the system.  
Normal Mounting 
Mount the unit to a firm vertical surface (flat on wall 
or in corner). 
1.  Remove front cover. 
2.  Temporarily loosen (do not remove) the screw 
holding the PC board in the detector base (see 
Figure 5 for location of this screw).  
 
The board can then be moved up or down for 
access to the knockout mounting holes in the 
base.