Honeywell International Inc. 8DL5898 Manuale Utente

Pagina di 8
     5898 Wireless DUAL TEC
®
 Motion Sensor  - Installation Instructions 
FR-Canadian 
 
PRELIMINARY DRAFT 5/18/09
 
3 - 
1
     SELECT MOUNTING LOCATION (See 
A
Additional guidelines for animal immunity: 
 
Mount the center of the sensor at 2.3 m (7.5 feet) high. 
 
Set the sensor to the Lowest or Low sensitivity (see step 6a). 
 
Install Animal Immune lens (5-532-489-01 - see Lens Change 
Instructions on page 3). 
 
Install the look-down mask (see Step 6a). 
 
Install the sensor where animals cannot come within 1.8 m (6 ft) of 
the sensor by climbing on furniture or other objects. 
 
Aim the sensor away from stairways, furniture or other objects that 
can be climbed on by pets. 
 
TEST the installation site to determine the exact level of attainable 
animal immunity.  
2
  REMOVE THE FRONT HOUSING (SEE 
B
3
     SELECT THE RANGE, SENSITIVITY AND PROTOCOL (SEE 
C
) 
4
  CONNECT THE BATTERIES (SEE 
D
5
  REGISTER THE SENSOR TO THE PANEL  
Refer to the control panel’s manual and the programming tool manual 
for information on registering wireless devices. 
Once you enter the sensor serial number into the panel programming, 
select the desired loop for that zone.   
Serial # 
/ LOOP 
 
 
Serial #1 
/ Loop 1 
High Sensitivity 
No Animal Immunity 
Pulse Count 1 
Serial #1 
/ Loop2 
Low Sensitivity / Animal 
Immunity [23 kg (50 lb.) / 45 
kg (100 lb.)] 
Pulse Count 2 
Serial #2 
/ Loop 1 
Low Temperature Trip 
When temperature drops 
below 7° C ± 2° C   
(45° F ± 4° F) for 5 minutes 
Low Temp Restoral 
When temperature 
rises + 2° C  
(+ 3° F) above low 
temperature trip point 
Serial #2 
/ Loop 2 
High Temperature Trip 
When temperature rises 
above  35° C ± 2° C   
(95° F ± 4° F) for 5 minutes 
Low Temp Restoral 
When temperature 
crops - 2° C  
(- 3° F) below high 
temperature trip point 
 
6
  MOUNT THE SENSOR (SEE 
E
7
  NORMAL WALK TEST– 10 MINUTES 
Normal walk test mode activates every time the front cover is closed 
and remains active for 10 minutes.  For an additional 10 minutes of 
walk test time, remove and replace the front cover.  In walk test mode, 
the LED is always enabled.  
Walk through the detection area and observe the LED.  
If necessary, adjust the microwave range, pulse count or sensitivity 
setting. (For LED activation meaning, refer to the LED Indicator table.) 
8  
MICROWAVE WALK TEST – 10 MINUTES 
1. Set the Microwave Walk Test DIP switch to ON, or toggle it ON and 
OFF. 
2. Set Range Adjustment potentiometer to 25% and replace the cover.   
3. Walk through the detection area and observe the LED.  
4. If necessary, adjust the potentiometer until desired detection range 
is obtained. (For LED activation meaning, refer to the LED Indicator 
table.) 
Power Up
Trouble or Anti-Mask
Fast Blinking Red (LED Enabled 
or Disabled)
Condition
Indicator LED
Slow Blinking Red (will finish within 
60 seconds)
Indicator LEDs
Normal Walk Test
Red ON for 3 seconds if Alarm
Yellow ON for 2 seconds if Microwave 
event detected
Green ON for 2 seconds if PIR event 
detected
Microwave Walk Test
Red ON if Microwave is set too high
Green ON if Microwave is set correctly
OFF if Microwave is set too low
 
TROUBLESHOOTING 
RED LED flashing rapidly during normal operation indicates a trouble 
condition.  A microwave, PIR, or temperature compensation fault is 
present, or a communication error has occured.  Supervision errors 
and low battery conditions are indicated at the panel.  
Solution:  Momentarily power down the sensor by removing and 
replacing all the batteries.  If the trouble does not clear, replace the 
sensor.   
 
SPECIFICATIONS 
Range:  50’ x 60’ (15 m x 18 m) [installed] 
35’ x 40’ (11 m x 12 m) [included] 
Batteries:  Four 1.5V AA Lithium Batteries (Use only Energizer L91) 
Battery Caution: Risk of fire, explosion and burns.  Do not 
recharge, disassemble, heat above 100° C (212° F), or incinerate.  
Dispose of used batteries promptly.  Keep away from children. 
Microwave Frequency:  24.125 GHz (K-band) 
RF Frequency:  345 MHz 
PIR White Light Immunity:  6,500 Lux typical 
Fluorescent Light Filter:  50 Hz or 60 Hz, switch selectable  
Operating Temperature:  -20° to 55° C  (-4° to 131° F),  
5% - 95% relative humidity (non-condensing) 
Self-Tests:  
Microwave supervision; End-to-End PIR self-test; Temperature 
Compensation 
Temperature Compensation:  Advanced Dual Slope 
PIR Fields of View:  
Wide Angle Lens (P/N 5-532-439-01) 
44 long range zones   
12 intermediate zones 
6 lower zones 
 
4 look-down zones 
Animal Immune Lens (P/N 5-532-489-01) 
44 long range zones   
36 intermediate zones 
18 lower zones 
 
4 look-down zones 
Dimensions:  4.93” x 2.93” x 1.68” (12.5cm x 7.5cm x 4.3cm) 
Weight:  149.0 g (5.26 oz); Packaged:  205.0 g (7.23 oz) 
Accessories:  
Optional Lens Kits -  
  Long Range Curtain Lens Kit  15 m x 3 m / 50’ x 10’  (P/N DT7000-LRLK) 
  High Security Lens Kit  11 m x 12 m / 35’ x 40’   (P/N DT7000-HSLK) 
  Pet Alley Lens Kit  11 m x 12 m / 35’ x 40’  (P/N DT7000-PALK) 
Mounting Brackets – 
  SMB-10 Swivel Mount Bracket (P/N 0-000-110-01) 
  SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01)  
Approval Listings:   
FCC 
IC 
CE,    C-Tick,    cULus Listed 
 
 
COMPLIANCE NOTES 
  Sensor must be tested once per year. 
  Sensor must have a clear line-of-sight to protected area.