WIRING TABLE 
Keypad
 
Control Panel
 
Wire Color 
G
 
Data In
 
Green 
 
 Aux Pwr (GND)
 
Black 
+
 
+ Aux Pwr
 
Red 
Y
 
Data Out
 
Yellow 
Note:  NO (normally Open) and C (common) are the 
connections for the relay output 
+
6150RF-003-V2
NO C
Y
G
 
Figure 2 - 6150RF Wiring Connections
 
 
APPLICATION GUIDELINES  
Use the following guidelines when planning an installation: 
 
Local wireless keys (wireless keys programmed directly into the 6150RF) may be used regardless of whether the 
RF receiver in the 6150RF is enabled or disabled. 
 
If using bi-directional devices, be sure to enable the transmitter module in the 6150RF. 
 
If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not 
exceed the number of receivers supported by the control panel.) 
 
If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be 
entered into the 6150RF. This user code must also be programmed into the control panel. 
 
You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID 
Source is the 6150RF (Local).
 
6150RF Application Guide 
The following guide outlines how to program the wireless keys, RF receiver, and the House ID in the 6150RF for your 
installation. 
*  Two 6150RFs are needed for this application: one assigned to partition 1 and one assigned to partition 2. 
**  If using an RF keypad on only one partition, the 6150RF’s partition assignment in panel programming must match the partition. 
*** If set for Local on a partition control, the 6150RF’s partition assignment must match the one programmed in the BD device.
 
Are you using
 
6150RF Programming Options 
System Control Panel
 
RF keys 
beyond 
system’s 
capacity?
 
RF receivers 
beyond 
system’s 
capacity?
 
RF keypads and/or 
Bi-directional 
devices on more 
than 1 partition?
 
Program 
Wireless Keys 
Into
 
Receiver 
Enable
 
House ID 
Source*** 
4110DL, 4110XM, 4140XMP, 
VISTA-20HWSE
 
N/A
 
N/A
 
N/A
 
6150RF
 
OFF 
 
Local [0] 
NO
 
NO
 
N/A
 
System
 
ON [1]
 
System [1] 
YES
 
NO
 
N/A
 
6150RF
 
ON [1]
 
System [1] 
VISTA-10P, VISTA-10SE, VISTA-
15, VISTA-15P, VIA-30PSE
 
YES
 
YES
 
N/A
 
6150RF
 
OFF [0]
 
Local [0] 
NO
 
NO
 
NO
 
System
 
ON [1]
 
System [1] 
YES
 
NO
 
NO
 
6150RF
 
ON [1]
 
System [1] 
YES
 
YES
 
NO
 
6150RF
 
OFF [0]
 
Local [0] 
NO
 
YES
 
YES*
 
System
 
OFF [0]
 
Local [0] 
VISTA-20SE, VISTA-20P
 
YES
 
YES
 
YES*
 
6150RF
 
OFF [0]
 
Local [0] 
NO
 
NO
 
NO**
 
System
 
ON [1]
 
System [1] 
YES
 
NO
 
NO**
 
6150RF
 
ON [1]
 
System [1] 
YES
 
YES
 
NO**
 
6150RF
 
OFF [0]
 
Local [0] 
NO
 
YES
 
YES
 
System
 
OFF [0]
 
Local [0] 
VISTA-40, VISTA-50P, VISTA-
128B, VISTA-128BP
 
YES
 
YES
 
YES
 
6150RF
 
OFF [0]
 
Local [0]