Honeywell International Inc. 8DL6150RFT2 Manuale Utente

Pagina di 8
- 6 - 
Step Action 
Display 
6. 
(Cont’d) 
Wireless Key Function Chart 
Function
 
Entry
 
Disarming
 
1
 
Arming Away
 
2
 
Arming Stay
 
3
 
Arming Maximum (Away Instant)
 
4
 
Arming Instant
 
7
 
Panic Alarm   
Produces type of alarm [* & #] 
programmed in control panel.
 
# + 99  
 
Manually Start a Relay Action
 
# + 7 (VISTA-10SE, VIA-30PSE) 
# + 7 + n (VISTA-10P, VISTA-15P, 
VISTA-20P, VISTA-20SE(HW))
 
Manually Stop a Relay Action
 
# + 8 (VISTA-10SE, VIA-30PSE) 
# + 8 + n (VISTA-10P, VISTA-15P, 
VISTA-20P, VISTA-20SE(HW)
 
Activate Relay as Programmed in 
Control
 
# + 71 (VISTA-40, VISTA-50P, 
VISTA-128B)
 
Activate Relay as Programmed in 
Control
 
# + 72 (VISTA-40, VISTA-50P, 
VISTA-128B)
 
Activate Access Control Relay for 
Partition
 
(VISTA-40, VISTA-50P, VISTA-
128B)
 
n = Device Number programmed in panel to be controlled
  
Press the [✻] key. 
Default Loop Functions 
5 8 0 4
Loop 3
Arm AWAY
Loop 1
Close on-board relay 
for 2 seconds
Loop 2
Disarm
Loop 4
Arm STAY
 
 
5 8 0 4 B D / 5 8 0 4 B DV
Loop 3
Arm AWAY
Loop 1
Close on-board relay 
for 2 seconds
Loop 2
Disarm
SET 
HOUSE 
CODE
••
• •
•••
Loop 4
Arm STAY
 
NOTE: If the loop is defaulted with a function (e.g., 
Arm, Disarm) and also is assigned to activate 
the on-board relay, the system performs 
BOTH functions. 
7. 
Repeat step 6 for the rest of the loops of the wireless key.  
 
8. 
To program a button on the wireless key to control the on-board 
relay, enter [5] (On-Board Relay Assignment).  
Flashes "o-." 
9. 
Enter the loop number of the wireless key (1-4). Enter the relay 
action (0 = no action; 1 = relay off; 2 = relay on; 3 = relay toggles on 
and off; 4 = relay closes for 2 seconds).  
Note: The relay action must be "0" for UL installations. 
Press the [✻] key. 
Flashing “o” and the loop number. 
Once the action is entered, displays “o” and 
alternately flashes the loop number and the relay 
action. 
10. 
Repeat step 9 for the rest of the loops. 
 
11. 
When all loops have been programmed for the wireless key, press the 
[✻] key. 
Flashes “d” followed by the device number. 
12. 
The 6150RF automatically displays the next available device number 
(one that does not have a serial number). 
If you want to program additional wireless keys, repeat steps 3 
through 10. Otherwise, press the [#] key.  This takes you back to the 
main display, which alternately flashes “oo” and “- -.” 
 
13. 
Enter [0] (High Security Mode). To put the system into High-Security 
mode, enter [1]. Enter [0] to disable. 
Flashes “En” and “0” alternately OR “En” and 
“1” if the keypad is in high-security mode 
14. 
Press [✻] to exit the 6150RF Program mode. 
 
Note:  Upon exiting the Program mode, the 6150RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit receiver 
address.  If either of these is incorrect, repeat steps 1 through 3 in the Programming for an Installation Without Local Wireless 
Keys section. 
Deleting, Replacing, or Editing Wireless Keys 
Use the following procedure to delete, replace, or change any of the programming for a wireless key. 
Step
 
Action
 
Display
 
1. 
Enter the Program mode by pressing the [1] and [3] keys 
simultaneously for a few seconds within 30 seconds after applying 
power. 
Alternately flashes "oo" and two dashes.
 
2. 
Enter [5] (Wireless Key Editing). Enter the device number for the 
wireless key you want to edit. This must be a device that has its 
serial number programmed in the 6150RF already. 
To delete the serial number, press [✻], then press [9], and press [✻] 
again.  
To exit without deleting the serial number, press the [#] key. 
Press the [✻] key to continue.
 
Flashes the device number and a hyphen. 
Once the device number is entered, alternately 
flashes "d" with the device number; and the serial 
number.