Honeywell International Inc. 8DLLYNXREN-5 Manuale Utente

Pagina di 72
  
–14– 
Mechanics of Programming 
 
General Programming Information 
Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. 
The system can be programmed at any time, even at the installer's premises prior to the actual 
installation. Simply apply power temporarily to the Control and then program the unit as desired. 
There are two programming modes:  
  Data field programming (used for setting various system options) 
  Interactive menu mode programming (used for programming zone information, programming Powerline 
Carrier Devices, and for entering transmitter serial numbers) 
The system can also be programmed remotely, using an IBM Personal Computer, a modem, and Compass 
Downloader for Windows. See the Remote Programming/Control (Downloading) section. 
Note:   You may find it convenient to adjust the volume setting before entering the Program Mode. This will allow you to clearly hear 
the feedback announcements or system beeps in the Programming Mode, of the system’s built-in speaker. To adjust the 
volume, press FUNCTION + VOLUME+ [3] or [6]. Upon exiting the Program Mode, the system will reset the volume to the 
default value (mid level). 
 
 
Entering Program Mode - Use one of the following methods to enter Programming Mode: 
1.  Press both the [
] and [#] keys at the same time, within 50 seconds after power is applied to the Control or 
from exiting Programming mode, OR 
2.  After power-up, enter the Installer Code (4112) + 800 (This method disabled if Program mode is exited using 
98.) to enter Expert Programming mode or Installer Code (4112) + 888 to enter Voice Prompt 
Programming mode. 
Note:  If a different Installer Code has been programmed, use that code to enter the Programming mode. Once you have entered the 
Program mode, data field 
20 (the first data field in the system) will be displayed and both keypad LEDs will flash. 
Programming a Data Field 
1. Press [
] + Field No. (for example, 
21), followed by the required entry.  
2. When you have completely programmed a data field, the keypad will “beep” three times and then 
automatically display the next data field in sequence.  To go to a different field, press [
] plus the desired field 
number. 
3.  If the number of digits that will be entered in a data field is less than the maximum number of digits available 
(e.g. phone number field), enter the desired data, then press [
] to advance to the next data field. 
4.  If a nonexistent field has been entered, the keypad will display “EE”. Simply re-enter [
] plus a valid field 
number. 
To view a data field without making changes: Enter [#] + Field No.  Data will be displayed for that field.   
To delete an entry
 in a field: Enter [
] + Field No. + [
]. (Applies only to fields 
40–
44, 
88 and 
94). 
Interactive Mode Programming (
56, 
80, 
81, 
83, 
84, 
85) 
Press [
] + interactive mode No. (for example, 
56). The keypad will display the first of a series of prompts.  
A detailed procedure (with displays of prompts) is provided in later sections of this manual.  
Interactive Mode 
Used to Program 
56 Enhanced Zone Programming Mode
 
Zone characteristics, report codes, and serial numbers
 
80 Device Programming Menu Mode
 
Powerline Carrier Devices
 
81 Zone List Menu Mode
 
Zone Lists for powerline carrier activation
 
83 Enhanced Sequential Mode
 
5800 Series transmitter serial numbers
 
84 Assign Zone Voice Descriptors
 
Voice descriptors for each zone
 
85 Record Custom Voice Descriptors
 
Up to 5 custom voice descriptors for zones
 
 
Loading Factory Defaults 
To load the factory defaults, enter the Programming mode, press 
97, then press number 1, 2, 3, or 4 to select 
from default tables 1-4 at the back of this manual, or press “0” if you are not selecting a default table. 
! 
If a default table is loaded, any data that has already been programmed into the system will be changed according to 
the default table selected! 
 
96 resets all subscriber account numbers and CSID in preparation for an initial download. 
Exiting Program Mode 
98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.  
99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice Prompt 
Programming mode using Installer Code (4112) + 888.  
Note:   After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press 
[#] + [0].