ademco 8DLPHS8-US Manuale Utente

Pagina di 2
HONYEYWELL 
PRELIMINARY
 
 
3G Communicator 
Lyric-3G / Lyric-3GC 
Installation Instructions
  
 
General Information 
The Lyric-3G/Lyric-3GC Communication Modules allow the Lyric Controller to communicate with the Central Station via 
the 3G cellular network. 
IMPORTANT: Before installing the communication module, make sure power (both AC and battery) is removed from the 
controller or use the “Install Cellular Module” mode described in the Replacing the Module section below. 
 
Installing the Lyric-3G Module 
1.  Install the provided FCC/IC label (P/N 800-19687) on 
the control’s case back. 
2.  Remove bezel from right-hand side of control to expose 
the radio module slot. To remove the bezel, push 
upward then slide it out. 
3.  Insert the module into the slot. Push firmly to mate the 
edge connector. Install the securing screw to ensure 
proper connection and operation. 
4.  Replace the bezel. 
5.  After all other controller connections are made, power 
up the controller.  
6.  Program and register the module during the controller’s 
initial association with its AlarmNet 360 account. Refer 
to the controller’s Programming Guide for details. 
7.  Check the signal strength before permanently locating 
the Lyric Controller. See Checking Signal Strength 
section. 
 
 
 
Typical FCC/IC Label Location 
 
 
 
 
Removing the Bezel 
 
 
 
Installing the Lyric-3G Module 
 
Replacing the Module 
In the event the module needs to be replaced, the Control must first be put in module replacement (“Install Cellular 
Module”) mode to avoid causing a tamper alarm or damaging the module. Module replacement mode deactivates 
tamper protection and removes power from the module connector for about 15 minutes. 
 
1.  Select  the Install Cell button.  
  User: Security –Tools – user code – Advanced – Install 
Cellular Module 
  Installer: Security –Tools – installer code – Test – 
Install Cellular Module 
  a.  Select Yes at the prompt to continue. 
  b.  A popup window displays steps for module 
replacement. Keep this window open until 
replacement is completed 
2.  Remove the side bezel. See diagram at right. 
3.  Remove the screw that secures the module. 
4.  Remove the communication module from its 
connection slot by using the pull tab. 
5.  Insert the new module into the slot. Push firmly to 
mate the edge connector. Replace the screw. 
6.  Replace the bezel. 
7.  When installation is complete, press OK at the 
replacement steps window. Confirmation of proper 
installation appears. Press OK to exit. 
 
 
 
 
 
SEE BOTTOM OF PAGE 2 
FOR AGENCY 
STATEMENTS