ademco 8DLPLS8-USR3 Manuale Utente

Pagina di 2
 
 
Communicators 
Lyric-LTE Series 
Installation Instructions  
 
General Information 
The Lyric-LTE series Communication Modules allow the Lyric Controller to communicate with the Central Station via the 
cellular radio network. The Lyric-LTE series includes the following models: 
• LYRICLTE-V (US, Verizon network) 
• LYRICLTE-A (US, AT&T network) 
• LYRICLTE-C (Canada) 
 
FIRST TIME INSTALLATION NOTE:
 Before performing the first time installation of the communication module, 
make sure power (both AC and battery) is removed from the controller and follow the Installing the Module (First 
Time Installation) steps.  
 
Installing the Module (First Time Installation) 
1.  Install the provided FCC/IC label on the control’s case back. 
  LYRICLTE-A & LYRICLTE-C: 800-22830 
LYRICLTE-V: 800-22830-1 
2.  Remove bezel from right-hand side of control to expose the 
communication module slot. To remove the bezel, push 
upward then slide it out. 
3.  Insert the module into the slot. Push firmly to mate the edge 
connector. 
4.  Replace the bezel. 
5.  After all other connections are made, power up the controller.  
6.  Program and register the module during the controller’s initial 
association with its AlarmNet 360™ account. Refer to the 
controller’s Programming Guide for details. 
 
 
 
Typical FCC/IC Label Location 
 
 
 
 
Removing the Bezel 
 
 
 
Installing the communicator Module 
 
7.  Check the signal strength before permanently locating the Lyric Controller. See Checking Signal Strength section. 
8.  Test the communication paths.  
 
Master User:
 
Security – Tools – [Master code] – Advanced – Comm. Test 
 
 
Installer: Security – Tools – [installer code] –Program – Comm. Diagnostcs - [V] – Test Communication 
  Press Send Cellular Message. Wait for “Ack Received” message.  
  Press Send Ethernet Message. Wait for “Ack Received” message. 
  “Ack Received” indicates successful communication. 
 
  If acknowledgement is not received, try one of the following: 
 
a.  Use an external antenna (see Using an External Antenna section). 
 
b.  Replace the radio with an alternate technology radio (ex., try 3G or CDMA). 
 
c.  Set the communication path to Wi-Fi-only.
 
 
Checking Signal Strength 
When choosing a suitable mounting location, check the 
communicator’s signal strength to ensure proper operation. For 
most installations, using the module’s internal antenna, mounting 
the Lyric controller as high as practical, and avoiding large metal 
components provides adequate signal strength.  
Use the Lyric Controller “Cellular Information” screen to display 
signal strength (in number of bars):  
  Security – Tools – [installer code] – Program – Comm. Diagnostics – 
Cellular Information 
 
Compare the signal strength number of bars displayed to the 
Signal Strength Guide values at right to ensure adequate signal 
strength. 
If using AlarmNet 360, check that the display is minimum 2 bars. 
If necessary, relocate the Controller to obtain better signal 
strength (press Cellular Information again to refresh the reading). 
 
Signal Strength Guide 
Panel display signal strength: range of 1-5bars; 
should be minimum 2 bars 
AlarmNet 360 Display:  
 
Must be minimum 2 bars lit.   
 
 
 
If adequate signal strength cannot be achieved, an external antenna should be used. See Using an External Antenna 
section on the other side.
 
 
PRELIMINARY