Honeywell International Inc. 9PGTPA-100A Manuale Utente

Pagina di 108
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Page  2109
                      
1 Dec 2003
34-45-4
7
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
NOTES:  (cont)
TABLE B. ANTENNA DELAY PROGRAM STRAPS
25. WHEN INSTALLING A 28 V DC PROCESSOR THE 115 V AC INPUT IS NOT USED FOR 
EITHER PRIMARY OR FAN POWER.
26. IVA-81( ) POWER GROUND AND DIMMING BUS INPUTS
CAS-100 Interwiring Diagram
Figure 2015 (Sheet 15 of 16) 
Differential
Add
MSB
LSB
Delay (nSec)
In (nSec)
Pin
7H
7J
0 - 50
0
0
0
51 - 150
100
0
1
151 - 250
200
1
0
251 - 350
300
1
1
1 = SELECTED PIN CONNECTED TO THE PROGRAM COMMON PIN - 7K
0 = PIN OPEN
SIGN PIN RBP - 7G
0 = ADD TIME DELAY TO TOP
1 = ADD TIME DELAY TO BOTTOM