Table 1003.   Mode S Line Maintenance Troubleshooting Procedure
 (Fault Indication on PPI or Dedicated Display)
Fault Annunciation
Remedy
XPNDR TOP ANT
XPNDR LOWER ANT
Check: 
Coaxial connectors 
Coax cable 
Coax switches 
Coax switch circuit defective 
Transponder antenna 
No. 1 XPNDR ALT DATA
No. 2 XPNDR ALT DATA
XPNDR ALT DATA No. 1 and No. 2
Check:
Altitude source 
Associated wiring 
SELECTED XPNDR 
XPNDR CONTROL DATA
Check Mode S transponder/control unit - Denotes 
loss/incorrect data not covered by other fault codes
XPNDR TCAS DATA  
No. 1 XPNDR DATA BUS
No. 2 XPNDR DATA BUS
Check: 
 
Max airspeed program pins 
Data bus wires (4) 
Mode S address wires 
Suppression coax cable 
Power wires/circuit breaker 
NOTE:  If a fault is indicated, perform a front-panel test of the Mode S transponder unit for further clarification of these 
problems.
Table 1004.   TCAS Line Maintenance Troubleshooting Procedure 
(Fault Indication on PPI or Dedicated Display)
Fault Annunciation
Remedy
MILACAS-FR
 PROCESSOR
UPPER ANTENNA
LOWER ANTENNA
ATTITUDE 
HEADING 
Perform 
MILACAS-FR
 Processor self test
Refer to 
paragraph 1.F.
TCAS FAIL/NO TCAS
TRAFFIC DISPLAY  
PPI or dedicated display failure.  
RA DISPLAY No. 1  
A single RA DISPLAY or RADIO ALT FAULT are not annunciated in a 
dual system unless other faults are present.  
RA DISPLAY No. 2
RA DISPLAY No. 1 and No. 2 
Check ADCs, VSIs, wiring, power. 
RADIO ALT No. 1 and No. 2 
TD FAIL
Check both radio altimeters. 
PPI failed.