NOTE: The ATC OFF function applies to the transponder. This function, as well as 
Modes 1, 2, 3/A, C, and S are independent of the MILACAS-FR and are 
individually selected on or off to support alternative foreign national 
mode/code signaling needs.
B. MILACAS-FR
The MILACAS-FR system controls extended squitter output power to manage emissions 
while it gives formation flight capability. UF19 formats are used to validate DF19 extended 
squitter messages and transmit formation flight coordination messages.
Table 1.   MILACAS-FR ATC Interoperability (cont)
Interrogation
Reply
IFF Transponder Mode
Mode / UF
ATC On
ATC Off
UF4
Replies with DF4/DF20
No Reply
UF5
Replies with DF5/DF21
Replies with DF5/DF21
UF11
Replies with DF11
No Reply
UF16
Replies with DF0/DF16
Replies with DF0/DF16
UF19
No Reply
No Reply
UF20
Replies with DF4/DF20
Replies with DF4/DF20
UF21
Replies with DF5/DF21
Replies with DF5/DF21
Intermode:
Mode 3/A
All-Call
No Reply
No Reply
Intermode:
Mode C
All-Call
No Reply
No Reply
Intermode:
Mode 3/A/S
All-Call
Replies with DF11
No Reply
Intermode:
Mode C/S
All-Call
Replies with DF11
No Reply