Honeywell International Inc. 9PGTPL-100A Manuale Utente

Pagina di 180
Page 23
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Table 7.   Aircraft Optional Equipment
Optional Aircraft Equipment
Description
Cockpit headphones
Augment the cockpit speaker with headset annunciations of 
advisory alert messages from the voice synthesizer in 
MILACAS-FR Processor.
External tone generator
and/or warning indicator
lamps
Supply additional visual and audible tone annunciations for 
advisory alerts from the MILACAS-FR Processor.
Advisory cancel switch
Permits the flight crew to cancel verbal advisory alerts on the 
cockpit speaker, cockpit headphones, tone generators, and 
alert lamps.
PPI modified to provide
TCAS traffic displays 
NOTE: PPI display is
used to show independent or combined 
radar and TCAS traffic on the same display.
Supplies separate or combined displays of weather/map 
data and TCAS traffic data. Display modes are selectable 
from the modified PPI control panel.
ARINC 429 (digital) or
ARINC 573 (non-digital) 
flight recorder 
Records TCAS data. Digital data is received on a low-speed 
ARINC 429 data bus from the MILACAS-FR Processor. 
Non-digital data is received as ARINC 573 parallel data from 
the MILACAS-FR Processor.
Performance management 
computer
Supplies climb rate performance limit discrete input to the 
MILACAS-FR Processor.
Wind shear system and/or
ground proximity system 
Supply TCAS advisory inhibit discrete inputs to the 
MILACAS-FR Processor during wind shear or ground 
proximity alarm conditions.
ARINC 615 data loader
(airborne or portable)
Reprograms the MILACAS-FR Processor program memory 
without requiring physical access to the unit itself. 
Programming is done through the ARINC 429 input and 
output ports on the MILACAS-FR Processor rear connector 
or a dedicated data loader connector on the front panel. Data 
loading may be done at either the low-speed or high-speed 
ARINC 429 data transfer rate. The data loader has an 
adapter cable (Honeywell P/N 300-80179-0501) to connect 
a portable data loader to the MILACAS-FR Processor front 
panel connector.