Page 30
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
C. MILACAS-FR System Leading Particulars
Table 13 and Table 14 show the leading particulars for the MILACAS-FR Processor and the 
ANT-81A Directional Antenna.
Leading particulars for the Mode S transponder system components and optional display 
units are described in separate manuals (shown in Table INTRO-1, Related Publications).
(1) MILACAS-FR Processor Leading Particulars
Table 13 shows the leading particulars of the MILACAS-FR Processor.
Table 13.   MILACAS-FR Processor Leading Particulars
Characteristic
Description
Form factor
6 MCU, ARINC Specification 600.
Maximum weight 
20 lb (9,07 kg) 
Power requirements
All except P/N
066-50000-03XX
P/N 066-50000-03XX
115 V 400 Hz, 150 Watts (maximum) and 26 V ac synchro 
reference power as required by ARINC 413A.
28 V dc 150 Watts (maximum) and 26 V ac synchro reference 
power as required by ARINC 413A.
Temperature Range
• Operating
• Storage
-67 °F to +158 °F (-55 °C to +70 °C)
-67 °F to +185 °F (-55 °C to +85 °C)
Cooling
ARINC 404/600 required or tray must be equipped with integral 
fan.
General requirements
Surveillance range and altitude 
volumes
See paragraph 3.A.
Threat evaluation criteria
See paragraph 3.B. 
Surveillance capacity
45 aircraft. However, TCAS will display up to 30 of the 
closest-range intruders.
Processor Mode S address capacity
150 addresses of detected Mode S-equipped aircraft.
System delay
Resolution advisory within 1.5 seconds after threat intruder is 
detected.
Voice synthesizer output power 
(nominal)
4 Watts into 8 ohms - speaker.