Honeywell International Inc. 9PGTPL-100A Manuale Utente

Pagina di 180
Page 34
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
5.
System Block Diagrams
A. General
The Honeywell MILACAS-FR System equipment shown in Figure 1 includes the following 
equipment:
(1) MILACAS-FR Processor
(2) ANT-81A Directional Antenna
(3) Mode S transponder (APX-100/APX-119) which includes a Mode S transponder and a 
transponder/TCAS control unit.
Omni beam characteristics 
Operational beam positions
Beam null compared to main beam
(at each elevation from -15 to +20)
360
°
≥9 dB
Input port VSWR 
1.5:1 maximum 
Antenna cable loss requirement
2.5 ±0.5 dB at 1030 MHz for each coaxial cable including 
connectors. 
Antenna cable differential phase delay
One-half wavelength maximum (approximately 5 inches) 
Maximum peak input power
1000 W pulsed
Maximum average input power
10 W continuous
ARINC characteristic
ARINC 735A
TSO
C119a (C119b for change 7 units)
Environmental certification 
In addition to the environmental requirements defined in 
Figure 4, an altitude immersion environmental 
specification requires that the antenna not outgas at an 
altitude of 55,000 feet when submersed in water for 30 
minutes.
Table 14.   ANT-81A Directional Antenna Leading Particulars (cont)
Characteristic
Description