COMPONENT MAINTENANCE MANUAL
Part No. 066-50007
3.
Leading Particulars
(TASK 34-42-37-870-803-A01)
A.
Unit Specifications
(Subtask 34-42-37-870-003-A01)
(1)
Table 3 lists the leading particulars for the ALA-52B.
Table 3. ALA-52B Leading Particulars
Characteristics
Description
Form Factor
ARINC 600 3 MCU
Dimensions
14.04 in. (35,66 cm) long by 3.56 in. (9,04 cm) wide by 7.64 in.
(19,41 cm) high
Weight
8.6 lb (3,9 Kg) maximum
Power Requirements
30W, +28 V dc
Temperature:
• Operating
5 to +158 F (-15 to +70 C)
• Storage
-67 to +185 F (-55 to +85 C)
Cooling
ARINC 600 forced air
Humidity
Zero to 95% relative humidity at 122 F(50 ºC)
Altitude
50,000 ft (15,240 m) above mean sea level
Warm-up period
Stable operation within 6 seconds
Frequency Range
4.235 to 4.365 GHz
Transmit Power
+26 dBm (nominal at antenna port)
Operating Range of Altitudes
-20 to 5000 ft (-6,1 to 1524 m)
Accuracy
±1.5 ft (0,46 m) or 2%, whichever is greater
Data Outputs
ARINC 429 range and CMC interface
Aircraft Installation Delays
40, 57, 80 ft
Pitch Limits
±20º
Roll Limits
±40º
Doppler Error
Compensated using dual slope FM ramp
Self-Test
Automatic in-flight, manual from discrete, ARINC 429, or front panel
Integrity Monitoring
Continuous self-monitoring establishes operational status at all
altitudes
Fault Reporting
Conforms to Boeing 777 formats
B.
Environmental Certification
(Subtask 34-42-37-870-004-A01)
(1)
The ALA-52B meets the environmental conditions of the RTCA document
number DO-160E, Environmental Conditions and Test Procedures for Airline
Electronic/Electrical Equipment and Instruments. Refer to Table 4.
EFFECTIVITY
ALL
34-42-37
Page 3
10 Oct 2007
© Honeywell International Inc. Do not copy without express permission of Honeywell.