2. System Leading Particulars
A. Unit Specifications
(1) Table 5 lists the leading particulars for the DMA-37B DME System.
Table 5. Leading Particulars
Characteristics
Description
General
Power Requirements
115 V ac, 380 to 420 Hz, 22 W (-0101, -0202, and -0303 only)
115 V ac, 360 to 800 Hz, 25 W (-1101 and -1212 only)
Weight
9.8 lb (4,45 kg)
Dimensions
See 
Figure 2005
.
Form Factor
ARINC 600 4 MCU
Cooling
ARINC 600 forced air
Temperature
• Operating
-67 to +158 °F (-55 to +70 °C) for -0101, -0202, and -0303 only
+5 to +158 °F (-15 to +70 °C) for -1101 and -1212 only
• Storage
-85 to +158 °F (-65 to +85 °C)
Humidity
Zero to 95% Relative Humidity
Warm-up period
Stable operation within one minute after application of power
Frequency Selection
Serial digital in accordance with ARINC 429
Range
Zero to 300 Nautical Miles
Altitude
50,000 feet above mean sea level
Velocity
Zero to 1000 Knots
Self Test
Continuous, automatic; Manual from discrete ARINC 429, CMC, or Front Panel
Integrity Monitoring
Continuous self-monitoring
Fault Reporting
ARINC 429 and ABD 0048B Centralized Maintenance Interfaces
Data Outputs
ARINC 429 Distance and CMC Interface
Certification
• -0101, -0202, and -0303
TSO C66c
DO-160C Environmental Category
/A2D2/ZCA/MNB/XXXXXXAEAEZUZ/XXE2/XX
ICAO Annex 10 FM Immunity
DO-189, DO-178B
• -1101
TSO  C66c
DO-160E Environmental Category
[(A2)(B2)V]BAB[SB]XXXXXXAA(WF)XA[R(WF)][ZW]RRRL[ZZZZ]XXAC
ICAO Annex 10 FM Immunity
DO-189, DO-178B