Honeywell International Inc. WLUWIFIM010 Manuale Utente

Pagina di 20
CAGE CODE: 
97896 
SCALE: NONE   
SIZE: A 
DWG NO.  
 
REV:  
 
SHEET 19 
HIF-1472R6(1) 
W
L
U
18 dBm output
3 dB cable loss
{
5 dB antenna gain
ERP = 20 dBm
 
Figure 11-1  Example ERP of the WLU with Sensor System Wi-Fi antenna 
 
12. 
FAULT ISOLATION 
12.1. 
General 
This section describes the built-in test equipment (BITE) function for the WLU. 
System BITE contributes to a number of maintenance functions: 
  Detection of internal and external faults 
  Reporting failure status in the air and on the ground 
  Ground test capability for isolating faults, performance verification, and system level testing. 
 
12.2. 
Fault Detection 
 
The WLU detects faults using continuous monitors in all system modes where the fault is 
detectable. The WLU continuously monitors for internal hardware, software and interface faults and 
sends fault messages via WLAN Manager, when they occur.  
 
The WLU automatically detects each fault condition that causes either:  
 
  One or more digital output signals to be identified as failed or invalid 
  Loss or significant degradation in other outputs to other systems. 
 
 
A fault is defined and set for each of the test components. Fault Monitor Data may include up to 600 
characters of free text to add details relevant to failures. The continually monitored tests cover the 
following components: 
 
  Power Supply (fault if power supply output is outside accepted range) 
  Processor (fault if processor error or overheat condition occurs) 
  Memory (volatile and non-volatile, fault if memory error occurs) 
  Software execution (fault is software error occurs) 
  Configuration (fault if configuration is corrupted)