Chapter  2: Installing the Scanner
19
5. Referring to the following illustration, remove the securing nut (1) from the
watertight gland and grommet (2), where the inter-unit cable (3) will enter
the base.
D3230-3
10
4
5
9
White wire
6
3
1
2
11
7
8
1
11
11 Securing nut  2
22
22 Gland  3
33
33 Inter-unit cable  4
44
44 Eight-way plug  5
55
55 Eight-way socket  6
 6
 6
 6
 6 Power cores (2 or 4)  7
77
77
Terminal clamp  8
88
88 Screwdriver  9
 9
 9
 9
 9 Cable clamp  10
10
10
10
10 Cable clamp screws 11
11
11
11
11 Ferrite clamp
6. Slide the gland nut onto the inter-unit cable (3), and insert the cable, still
covered by its protective sleeve, through the gland into the base.
7. Cut and remove the protective sleeve to expose the 8-way plug (4) and
power cores (6).
8. If the scanner is connected to an HSB Series Pathfinder Radar display, fit
the ferrite clamp (11), supplied loose with the display unit, as follows:
CAUTION
If any wires are damaged when the clamp is fitted, the scanner unit will
not function correctly.
- the ferrite clamp is supplied open. If the clamp has been closed, insert a
small, flat-blade screwdriver into the slots at the end of the clamp
opposite the hinge and twist gently.
- Position one-half of the clamp around the eight cores of the inter-unit
cable between the 8-way plug (4) and the cable clamp, as close to the 8-
way plug as possible. (It may be necessary to fit the clamp over the
cable tie closest to the 8-way plug – this will not affect the ferrite
clamp’s function).
154_3c2.p65
13/12/99, 17:02
19