HARRIS CORPORATION KRC121107-1 Manuale Utente

Pagina di 129
Operations and Maintenance
6
Hardware Replacement
When a faulty unit has been determined either by indications at the MSC, by
routine maintenance checks, or by using the troubleshooting procedure, the
unit can be replaced by following the appropriate procedure in this section.
Warning!
If possible avoid “hot repair” of CRI units. Hot repair is the process of
replacing a failed unit without powering down the CRI cabinet.
Before replacing any unit, contact the MSC for further assistance. The MSC
may have to block one or more units before they can be replaced.
6.1
Prerequisites and Tools
6.1.1
Prerequisites
Before a faulty magazine or unit can be replaced, the replacement magazine
or unit must be available and have the same or higher R-state number (R-state
letters do not matter). For example, product number ROF 134 8002/1 R3B
can be replaced with product number ROF 134 8002/1 R3C, but not with
ROF 134 8002/1 R4A.
6.1.2
Tools and Materials
The following tools are recommended for the equipment replacement
procedures:
ESD wrist strap with "banana" connector
Extractor tool for removing cards (handle and button)
Cable connector torque wrench set including:
Torque wrench (preset to 0.6 Nm and 2.8 Nm)
Torx bit TX10 and TX8 for circuit board screws
SMA tool for coaxial cables
Flat blade screwdriver set for power and data cable connectors
Phillips screwdriver set
1/1541-AE/LZB 119 3834 Uae Rev PA6 2001-04-04
6-9