Motorola Solutions Inc. 89FT7008 Manuale Utente

Pagina di 36
8
 
First Time Battery Charge
The first time battery charge ensures maximum start capacity for 
the battery. Charge your new battery for at least 24 continuous 
hours before using it or until the LED indicator of the UOD shows 
green. During the charge, the LED indicator of the PowerPad 
shows green and blinks quickly. The UOD charges your battery 
effectively when it is at room temperature [approx. 68°F (20° C)]. 
Battery charging temperature range is 32°F
 
to 113°F
 
(0
°
C to 45
°
C). 
Table 1: Status of a UOD Slot LED During Battery Charge
Slot LED Status 
Indication
No Light
No device inserted.
Blinking Amber
Battery temperature out of tolerance and 
charging has been temporarily stopped.
Solid Amber
PowerPad Battery is being charged.
Solid Green
PowerPad Battery is at least 90% charged 
after 2.5 hours and fully charged after 3.
Solid Red
PowerPad Battery is not fully charged 
after 3 hours of charging, and is consid-
ered failed.