INSTALLATION
INSTRUCTIONS
Product Summary
The System Sensor™ Smoke Sensor Model 2100ARFT 
(smoke alarm) is a Learn Mode, wireless, photoelectric 
smoke sensor with a self-contained alarm siren, a low-
battery annunciator, and a status light. The smoke 
alarm is part of a security/fire alarm system and com-
municates with the system’s control panel.
Figure 1 illustrates the smoke sensor’s parts.
Installation Guidelines
ν
Avoid installing the unit until all contsruction is 
completed. The mounting ring may be pre-
installed.
ν
Leave the orange dust cover on the unit until 
sheet rocking and sanding are completed; other-
wise, dust can get into the unit and cause false 
alarms.
CAUTION:
The orange dust cover must be 
removed for the unit to detect 
smoke.
ν
Do not mix battery brands.
ν
Not compatible with CareTaker Plus or custom 
versions with software versions 3.0 or earlier.
ν
Not compatible with Commander 2000 or custom 
versions with software versions 4.0 or earlier. 
(The Commander 2000 announces the version 
when it is powered up or reset.)
Tools Needed
ν
Phillips screwdriver and pocket-sized slotted 
screwdriver
Batteries
UL Note:
Each smoke alarm uses two 3-volt lithium 
batteries. For UL installations, use one of 
the following: Sanyo CR123A, Panasonic 
CR123A, or Duracell DL123A. Do not mix 
brands.
Inserting Batteries
The batteries must be correctly installed before the 
panel can learn the smoke alarm ID. [Batteries are 
shipped in the unit backwards.] You must remove 
them and reinstall them correctly.
To insert batteries into the smoke sensor:
1.
Gently twist the cover counterclockwise to sepa-
rate it from the mounting bracket.
2.
Remove the batteries from the battery compart-
ment.
3.
Insert the batteries into the battery compartment. 
Observe proper polarity.
4.
Leave the mounting ring off and proceed to 
“Learning the Smoke Sensor.”
Low Batteries
When the batteries need to be replaced, the unit trans-
mits a signal to the panel. If the batteries are not 
replaced within 7 days, the unit will chirp every 40 
seconds until the batteries are exhausted.
Note:
If you test the smoke alarm or it goes into 
alarm during this 7-day period, chirp delay is 
canceled and the unit begins chirping immedi-
ately.
Programming
For more detailed programming information, refer to 
the specific panel’s installation manual.