Ericsson Radio Systems AB CKRC1311004-1 Manuale Utente

Pagina di 406
Environmental Capabilities
3.6
Handling -40
C - +70
C
3.6.1
General Conditions
This section refers to shorter periods of transport and storage in
unpacked conditions. Precautions to avoid condensation before
subjecting the equipment to operational conditions are necessary.
3.6.2
Climatic Conditions
During handling the equipment withstands the conditions stated in
Section 3.4.2 on page 16 in this document.
3.6.3
Biological Conditions
During Handling the equipment withstands the conditions stated in
Section 3.4.3 on page 16 in this document.
3.6.4
Chemically Active Substances
During Handling the equipment withstands the conditions stated in
Section 3.4.4 on page 16 in this document.
3.6.5
Mechanically Active Substances
During Handling the equipment withstands the conditions stated in
Section 3.4.5 on page 17 in this document.
3.6.6
Mechanical Conditions
The equipment endures stresses normal for handling, during handling
the equipment withstand the conditions stated in Section 3.4.6 on page
17
in this document.
3.7
Operation Indoor +5
C - +40
C
3.7.1
General Conditions
The severity of these requirements is in conformity with: IEC 721-3-3
classes 3K3/3Z2/3Z4/3B1/3C2(3C1)/3S2/3M1. and ETS 300 019-1-3
Class 3.1 "TEMPERATURE-controlled locations".
This clause refers to the environment which an RBS for indoor use
shall endure.
Note:
The different operating temperature levels according to Safe
function and Non-destruction, refer to situations where the
RBS is supposed to have been operating in "normal
condition" mode for a certain time. Then the surrounding
temperature in the compartment increases (decreases)
according to these figures. Accordingly, this means that the
surrounding temperature is allowed to change within the
limits while the RBS still operates and has its own loss of
energy.
EN/LZT 720 0024
R2A
2002-11-01
19 (34)
© Ericsson Radio Systems AB
— All Rights Reserved —