Ericsson Radio Systems AB CKRC1311004-1 Manuale Utente

Pagina di 406
Environmental Capabilities
Table 14
Environmental Parameters
Unit
Value
Normal Condition
Non-destruction
Temperature
C
-33 - +55
-40 - +70
Relative humidity
%
5 - 100
5 - 100
Absolute humidity
g/m
3
0.26 -40
0.26 - 40
Change of temperature
C/min
6
6
Rain temperature
C
5
5
Vibration sinus:
displacement
mm
3
acceleration
m/s
2
10
frequency
Hz
2 - 9
9 - 200
Vibration random:
ASD
m
2
/s
3
0.5
0.2
frequency
Hz
2 - 200
200 - 500
Shock:
peak acc.
m/s
2
100
1)
duration
ms
11
Fauna
none
Not Appl.
Not Appl.
1)
The requirements belong to the Safe function with one exemption:
performance of the RBS shall be verified as "no loss of calls".
EN/LZT 720 0024
R2A
2002-11-01
25 (34)
© Ericsson Radio Systems AB