IQ Group Ltd WL3650 Manuale Utente
Instruction Manual -
Battery operated Motion Sensing Landscape Light
Item: XX-XXXX
SAFETY INFORMATION
BATTERY CAUTION & DISPOSAL
● Unit is suitable for landscape and garden use.
● Clear the surrounding where your installation will take place.
● Make sure the spike is installed completely into the ground.
● The device is not a toy, do not allow children to play with it.
● Do not attempt to install during bad weather, if you are suffering from
nausea or dizzy spells or on medication with similar side effects.
● When not in use, store it properly.
PACKAGE CONTENT
GENERAL INFORMATION
● 50 lumens of LED light to brighten up your landscape and garden
● Channel linking feature between a group of devices
● Anti-glare illumination
● 360° detection sensor for wide coverage
● No wiring require
● Battery operated
● Easy installation
● Weather resistant
INSTALLATION
Tools required
Battery required
● Work gloves
● Safety goggles
● Trowel
● L shaped ruler
● Rubber mallet
Install The Batteries
Insert 3 pcs of C cell alkaline batteries.
Make sure batteries are in the correct polarity.
Warm up time is 15 sec after installation of batteries.
Adjustment
This device comes with sensor, channel and time adjustment features. Before start installation on
the ground, please select the desire setting follow the instruction.
Lux Learn
You can control the sensor activation
by lux reading which can be recorded
by your device. The device can be
activated during the day and night
depending on the lux reading
recorded. The default mode reading is
5 lux.
● Press once within 1 sec to start lux
recording. The light will blink twice
after 8 sec. This indicate that the
device already captured the lux
reading.
● To set it to default setting, press
twice within 5 sec. The light will
blink twice to indicate that you have
returned to default mode.
Dark Mode & Channel A, B, C
Dark mode indicates at dusk, only after
sensor activation, light will on in 100%
of brightness. The device does not light
on when there is no sensor activation.
Select channel A, B or C to create
sensor link action. You need to have
more than one device in order to
perform the linking function.
Switch to Channel A on all your
devices. When a detection is activated,
the lights from all Channel A device will
turn on. Same method apply to Channel
B and C selection. Sensor linking
distance between devices is maximum
50m.
Dim Mode & Channel A, B, C
Dim mode indicates at dusk, the light will
turn on in dim brightness as a guide light
even there is no sensor activation. You
can adjust the Lux Learn controller to set
Dim Mode at dusk (refer to Lux Learn).
When device is activated, light will turn on
in 100% of brightness.
Select channel A, B or C to create sensor
link action. You need to have more than
one device in order to perform the linking
function.
Switch to Channel A on all your devices.
When a detection is activated, the lights
from all Channel A device will turn on.
Same method apply to Channel B and C
selection. Sensor linking distance between
devices is maximum 50m.
Time
You can select OFF, 10 sec, 30 sec or 60 sec. The light
will stay on for the time selected after motion is no
longer detected. Select OFF to completely switch off
the device.
Installing The Device
Select a location where it is flat, clear of obstacle and a grass land. There are 4 options of installation method for your choice.
2. Push the post down to attached it to the spike
(FIG 6).
3. Assemble the light by screw in fixture (FIG 7).
Make sure to fix it tightly with two indication
lines match together (FIG 8).
● Do not mix old and new batteries.
● Do not mix Alkaline, Standard (Carbon-Zinc) or Rechargeable (Nickel
Cadmium) or (Nickel Metal Hydride) batteries.
● Do not dispose of batteries in fire.
● Batteries should be recycled or disposed of as per state and local
guidelines.
(FIG 4)
(FIG 5)
(FIG 7)
READ ALL INSTRUCTIONS
KEEP FOR FUTURE USE
x 4pcs
x 4pcs
x 4pcs
1. Attach the spike.
1. Attach the spike.
C cell alkaline batteries x 3pcs
(Not included)
1. Using rubber mallet to drive part of the spike into
the ground, use L shaped ruler to check and
make sure the fixture is not tilted to one side
(FIG 4). Finally, drive the spike into the ground
until the top of the stake is flush with the ground
(FIG 5).
(FIG 6)
(FIG 8)
OPTION 1
OPTION 2
OPTION 3
3. The spike should be pushed into the ground
until the top of the stake is flush with the ground
(shown in A, FIG 2).
4. Assemble the light by screw in fixture
(shown in B, FIG 2). Make sure to fix it tightly
with two indication lines match together (FIG 3).
(FIG 1)
(FIG 2)
A
B
(FIG 3)
2. Using both hands, push the spike into the
grass land (FIG 1). This will work in areas with
good soft soil and places that have had rain
frequently.
Use L shaped ruler to check and make sure the
fixture is not tilted to one side.
(FIG 9)
(FIG 10)
2. Dig hole with a trowel (FIG 9).
3. Place the spike in the hole until the top of
the stake is flush with the ground. Cover
it with soil and press the soil to make
sure the spike is buried firmly (shown in
A, FIG 10).
4. Assemble the light by screw in fixture
(shown in B, FIG 10). Make sure to fix it
tightly with two indication lines match
together (FIG 11).
(FIG 11)
A
B
Caution
DO NOT push the
complete fixture to the
ground from the top.
This might cause
damage to sensor and
light portion.