IQ Group Ltd WL3650 Manuale Utente

Pagina di 3
Instruction Manual - 
Battery operated Motion Sensing Landscape Light
Item: XX-XXXX
SAFETY INFORMATION
BATTERY CAUTION & DISPOSAL
● Unit is suitable for landscape and garden use.
● Clear the surrounding where your installation will take place.
● Make sure the spike is installed completely into the ground.
● The device is not a toy, do not allow children to play with it.
● Do not attempt to install during bad weather, if you are suffering from 
nausea or dizzy spells or on medication with similar side effects.
● When not in use, store it properly. 
PACKAGE CONTENT
GENERAL INFORMATION
● 50 lumens of LED light to brighten up your landscape and garden
● Channel linking feature between a group of devices
● Anti-glare illumination
● 360° detection sensor for wide coverage
● No wiring require
● Battery operated
● Easy installation
● Weather resistant
INSTALLATION
Tools required
Battery required
● Work gloves
● Safety goggles
● Trowel
● L shaped ruler
● Rubber mallet
Install The Batteries
Insert 3 pcs of C cell alkaline batteries.
Make sure batteries are in the correct polarity.
Warm up time is 15 sec after installation of batteries.
Adjustment
This device comes with sensor, channel and time adjustment features. Before start installation on 
the ground, please select the desire setting follow the instruction.
Lux Learn
You can control the sensor activation 
by lux reading which can be recorded 
by your device. The device can be 
activated during the day and night 
depending on the lux reading 
recorded. The default mode reading is 
5 lux.
● Press once within 1 sec to start lux 
recording. The light will blink twice 
after 8 sec. This indicate that the 
device already captured the lux 
reading.
● To set it to default setting, press 
twice within 5 sec. The light will 
blink twice to indicate that you have 
returned to default mode.
Dark Mode & Channel A, B, C
Dark mode indicates at dusk, only after 
sensor activation, light will on in 100% 
of brightness. The device does not light 
on when there is no sensor activation.
Select channel A, B or C to create 
sensor link action. You need to have 
more than one device in order to 
perform the linking function.
Switch to Channel A on all your 
devices. When a detection is activated, 
the lights from all Channel A device will 
turn on. Same method apply to Channel 
B and C selection. Sensor linking 
distance between devices is maximum 
50m.
Dim Mode & Channel A, B, C
Dim mode indicates at dusk, the light will 
turn on in dim brightness as a guide light 
even there is no sensor activation. You 
can adjust the Lux Learn controller to set 
Dim Mode at dusk (refer to Lux Learn). 
When device is activated, light will turn on 
in 100% of brightness.
Select channel A, B or C to create sensor 
link action. You need to have more than 
one device in order to perform the linking 
function.
Switch to Channel A on all your devices. 
When a detection is activated, the lights 
from all Channel A device will turn on. 
Same method apply to Channel B and C 
selection. Sensor linking distance between 
devices is maximum 50m.
Time
You can select OFF, 10 sec, 30 sec or 60 sec. The light 
will stay on for the time selected after motion is no 
longer detected. Select OFF to completely switch off 
the device.
Installing The Device
Select a location where it is flat, clear of obstacle and a grass land. There are 4 options of installation method for your choice.
2. Push the post down to attached it to the spike 
(FIG 6).
3. Assemble the light by screw in fixture (FIG 7).
  Make sure to fix it tightly with two indication 
lines match together (FIG 8).
● Do not mix old and new batteries.
● Do not mix Alkaline, Standard (Carbon-Zinc) or Rechargeable (Nickel 
Cadmium) or (Nickel Metal Hydride) batteries.
● Do not dispose of batteries in fire.
● Batteries should be recycled or disposed of as per state and local 
guidelines. 
(FIG 4)
(FIG 5)
(FIG 7)
READ ALL INSTRUCTIONS
KEEP FOR FUTURE USE
x 4pcs
x 4pcs
x 4pcs
1. Attach the spike.
1. Attach the spike.
C cell alkaline batteries x 3pcs 
(Not included)
1. Using rubber mallet to drive part of the spike into 
the ground, use L shaped ruler to check and 
make sure the fixture is not tilted to one side 
(FIG 4). Finally, drive the spike into the ground 
until the top of the stake is flush with the ground 
(FIG 5).
(FIG 6)
(FIG 8)
OPTION 1
OPTION 2
OPTION 3
3. The spike should be pushed into the ground 
until the top of the stake is flush with the ground 
(shown in A, FIG 2).
4. Assemble the light by screw in fixture 
(shown in B, FIG 2). Make sure to fix it tightly 
with two indication lines match together (FIG 3).
(FIG 1)
(FIG 2)
A
B
(FIG 3)
2. Using both hands, push the spike into the 
grass land (FIG 1). This will work in areas with 
good soft soil and places that have had rain 
frequently.
  Use L shaped ruler to check and make sure the 
fixture is not tilted to one side. 
(FIG 9)
(FIG 10)
2. Dig hole with a trowel (FIG 9). 
3. Place the spike in the hole until the top of 
the stake is flush with the ground. Cover 
it with soil and press the soil to make 
sure the spike is buried firmly (shown in 
A, FIG 10).
4. Assemble the light by screw in fixture 
(shown in B, FIG 10). Make sure to fix it 
tightly with two indication lines match 
together (FIG 11).
(FIG 11)
A
B
Caution
DO NOT push the 
complete fixture to the 
ground from the top. 
This might cause 
damage to sensor and 
light portion.