Bosch Security Systems BV NDE8000 Manuale Utente

Pagina di 42
32
en | Troubleshooting
FLEXIDOME IP starlight 8000i
2018.11 | 01 |
Installation Manual
Bosch Security Systems
7
Troubleshooting
7.1
Resolving problems
The following table is intended to help identify the causes of malfunctions and correct them
where possible.
Malfunction
Possible causes
Solution
Unit does not operate.
Power failure.
Check power supply.
Faulty cable connections.
Check all cables, plugs,
contacts and connections.
No connection
established, no image
transmission.
Incorrect unit configuration.
Check all configuration
parameters (reset to factory
default if necessary).
Faulty installation.
Check all cables, plugs,
contacts and connections.
Wrong IP address.
Check the IP addresses (ping).
Faulty data transmission within
the LAN.
Check the data transmission
with ping.
The maximum number of
connections has been reached.
Wait until there is a free
connection and call the
transmitter again.
No audio transmission to
remote station.
Hardware fault.
Check that all connected audio
units are operating correctly.
Faulty cable connections.
Check all cables, plugs,
contacts and connections.
Incorrect configuration.
Check audio parameters on the
Audio configuration and LIVE
page functions pages.
The audio voice connection is
already in use by another
receiver.
Wait until the connection is free
and then call the sender again.
The unit does not report
an alarm.
Alarm source is not selected.
Select possible alarm sources
on the Alarm sources
configuration page.
No alarm response specified.
Specify the desired alarm
response on the Alarm
connections configuration page;
if necessary change the IP
address.
The unit is not
operational after a
firmware upload.
Power failure during
programming by firmware file.
Have the unit checked by
Customer Service and replace if
necessary.