Test Conditions 
DO-160G 
Test Description
9
 
Power Input  
16.0 
Equipment tested to Category BXX for 28 V  
•  Normal Operation: 18.0 to 32.2 V 
•  Surge (high): 60 VDC for 100 ms + 40 VDC for 1 
second 
•  Surge (low): 17 VDC for 30 ms 
Voltage Spike  
17.0 
Equipment tested to Category B  
•  Voltage spike with 56 V peak for 10 microseconds 
(approx. trapezoidal shape). Test source output 
impedance 50 ohm (see DO-160F Figure 17-1) 
Audio frequency conducted 
susceptibility  
18.0 
Equipment tested to Category B  
Induced signal susceptibility  
19.0 
Equipment tested to Category AC 
•  Magnetic Fields Induced in the UUT 
•  Magnetic Fields Induced into interconnect cables 
•  Electrical Fields Induced into interconnect cables 
•  Induced Voltage Spikes into interconnect cables 
Radio frequency susceptibility  
20.0 
Equipment tested to Category T 
•  Conducted: between 10 kHz to 400 MHz 
•  Radiated: 100 MHz to upper limit (10 GHz?) 
Radio frequency emission  
21.0 
Equipment tested to Category B 
•  Conducted: 150 kHz to 152 MHz 
•  Radiated: 100 MHz to 6 GHz 
•  Measurement Bandwidth: 150kHz to 6GHz 
Lightning induced transient 
susceptibility  
22.0 
Equipment identified as Category XXXXX – no test required  
Lightning direct effects  
23.0 
Equipment identified as Category X – no test required  
Icing  
24.0 
Equipment identified as Category X – no test required  
Electrostatic Discharge  
25.0 
Equipment identified as Category X – no test required  
Fire, Flammability 
26.0 
Per AC 25-16F Paragraph 7(h), we shall conduct these tests 
in accordance with Appendix F of 14 CFR Part 25 (FAA does 