•  Do not use extension cords etc. Only plug the product into a grounded wall outlet.
•  Avoid installing the product in damp areas.
•  Make sure to drain the RolliCool with the included drainage pipe.
1.3 – FCC Information
DECLARATION OF CONFORMITY:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received, including interference 
that may cause undesired operation.
FCC RELATED INFORMATION:
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning 
the equipment off  and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit diff erent from that to which the 
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized 
modifi cations to this equipment. Such modifi cations could void the user’s authority to operate 
the equipment.
1.4 – Disposal at End-of-Life
This product must not be disposed of by incineration, landfi lling, or mixing with household 
trash. Improper disposal of the battery contained within this product may result in the battery 
heating up, rupturing, or igniting which may cause serious injury. The refrigerants contained 
inside the RolliCool present chemical risks to the environment. The recommended disposal 
for any RolliCool Portable Air Conditioner at its end-of-life is to dispose of the entire unit by 
contacting your local recycling company. Local regulations and laws pertaining to the recycling 
and disposal of any RolliCool unit and/or products containing them will vary according to your 
country, state, and local governments. You must check laws and regulations corresponding to 
where you live in order to dispose of your RolliCool unit properly. It is the user’s responsibility to 
dispose of their equipment properly in accordance with local regulations and laws.
For additional information about where you should drop off  your RolliCool unit, please contact 
your local or regional waste management offi
  ce, your household waste disposal service, or your 
point-of-sale.
15
RolliBot RolliCool Portable AC User Manual
3. Remove the fi lter and soak it in lukewarm water or use a vacuum to clean the fi lter. Mild 
detergents may be used.
4. After the fi lter has completely dried, reinstall it.
CLEANING THE LOWER FILTER
1. Reach under the notch and remove the fi lter.
2. Soak it in lukewarm water or use a vacuum to clean the fi lter. Mild detergents may be used.
3. After the fi lter has completely dried, reinstall it. 
6.3 – How to Drain the Unit
In most cases, the AC unit will not require draining. If this is necessary in some special case, the 
unit will sound an alarm and the display will show the icon  
to indicate the water reservoir 
inside is full. 
• 
 Please make sure your AC unit is completely powered off  before performing any type of maintenance. 
• 
If relocating the unit before draining, move it carefully so as not to spill the water inside the reservoir.
• 
 Make sure the Drainage Pipe, has adequate space underneath for draining. If using the Lower Drainage Opening, 
ensure there is a suitable area for water runoff . If using the Upper Drainage Opening, fetch a container for water runoff  
before connecting the pipe.
• 
Keep the drainage cover and the water plug on at all times when not 
draining the unit.
• 
When draining the unit, do not allow the Power Cord to come in contact 
with water.
• 
During drainage, the unit may be tilted slight backwards to promote 
faster drainage.
• 
 Keep in mind the unit may hold more water than expected. If using a 
container, do not use a small one or either take care of drainage outdoors.
USING THE LOWER DRAINAGE OPENING
1. Turn off  and unplug the unit.
2. Move the unit to a suitable location for drainage.
3. Remove the cap from the opening.
4. Allow the water to drain. 
5. After draining is complete, it is recommended to 
turn the unit on and run it in Fan Only Mode at 
the lowest speed for at least two hours in order to 
ensure the Drainage Pipe dries inside. 
6. Reinstall the cap.
USING THE UPPER DRAINAGE OPENING
1. Turn off  and unplug the unit.
2. Move the unit to a suitable location for drainage if 
needed.
3. Place a container near the unit.
4. Place the end of the Drainage Pipe in the container.
Rollibot-PortableAC-UM-0403.indd   Spread 6 of 10 - Pages(6, 15)
Rollibot-PortableAC-UM-0403.indd   Spread 6 of 10 - Pages(6, 15)
4/6/2017   6:07:07 PM