Installation Instructions
 
4. Connect Senzit Monitoring Device Power 
Cable. 
NOTE: Senzit power cable must also be wired to 
power supply. See “Wiring Instructions” for power 
supply wiring instructions. 
 
5. Turn Key to accessory/on position to Power On 
the Senzit Monitoring Device Green LED indicator 
illuminates to signal that indicator has power. 
 
 
1. Turn Engine Off 
2. Remove port cover or 
existing indicator from air 
handler service port. Inspect 
service port and fittings for 
damage. 
Note: Do Not attempt to install 
Senzit Monitoring Device by 
screwing into sensor port by 
hand. 
 
 
 
 
 
1. Install Senzit Monitoring Device. 
a. Loosen the Senzit Monitoring Device’s Service Port Release Nut by rotating in a counter-clockwise 
direction (1 inch wrench). 
b. Connect Monitoring Device’s Mounting Adapter to air handler service port and tighten (7/16 inch 
wrench). Caution: Do not exceed 1.8 ft-lbs (2.5 Nm) Over tightening may damage threads. 
c. Tighten Senzit Monitoring Device’s Service Port Release Nut by rotating 1/2 turn in a clockwise 
direction (1 inch wrench). Caution: Over tightening may damage threads. 
Note
: Adapters may be required for installation (M10x1 to 1/8 - 27 NPT). 
Previously used fittings may be reused provided they are undamaged and do not restrict air flow.