1. Implementation standards:
China national standard GB/T778.1-2007/ISO4064-1:2005 
Water flowrate measurements of drinking cold water meters and hot water meters in 
Closed full pipelines   
2. Main technical parameters
Item 
Parameters 
Model 
PWM
15
PWM2
0
PWM2
Diameter 
DN15 
DN20 
DN25
Overload 
flowrateQ (m
3
/h)
3.125 
5.0 
5.0 
Permanent flow rate Q
3
(m
3
/h) 
2.5 
4.0 
4.0 
Transition flow rate Q
2
(m
3
/h) 
0.025 
0.04 
0.04 
Minimum flow rate Q
1
(m
3
/h) 
0.015 
0.025 
0.025 
Q
/ Q
1
 
R160 
Accuracy class 
Medium temperature range 
T50(0.1℃~50℃) 
Sensitivity class of flow profile 
U5,D3 
Pressure loss at Q3 
ΔP63 
Hydraulic pressure class 
MAP16 
Ambient class 
Class C 
Protection class 
IP68 
Compatibility class of 
electromagnetism 
E1 
Meansurment cycle 
Once/250ms