Fiber Mountain Inc SENFG1MA Manuale Utente

Pagina di 46
  
 
© Copyright 2018, Fiber Mountain, Inc. All Rights Reserved 
26 
Sensus Installation Manual 
150-00006 Rev 5 
4. 
Installation of Sensus 
4.1  Installing Modules into the Sensus Chassis 
All modules are attached to the chassis by the backplane connection point and two small 
spikes in the chassis. To install the patching modules:  
1.  Insert the management module into the designated middle slot (slot 2) 
2.  Push the management module all the way back until it snaps into place. The patching 
module should make complete contact with the backplane 
3.  Insert the patching modules into the designated left or right slot (slots 1 and 3). Guide pins 
on the bottom interior of the chassis should line up with the guides on the bottom of the 
patching modules. Patching modules should also make complete contact with the 
backplane 
4.  Tighten all thumbscrews in the rear to secure the modules to the chassis, two screws per 
module 
Sensus patching modules are hot-swappable. To remove a patching module, loosen the 
thumbscrews on the rear of the device. Press on the screws to push the module out of the chassis. 
 
Figure 4-1 Sensus Module Slots