Maxiiot Ltd GL5712UX Manuale Utente

Pagina di 15
LoRa Concentrator Card_GL5712_Datasheet_V1.0.0
Maxiiot Ltd
www.maxiiot.com
6
3.3 Absolute maximum rating
Table3.2 absolute maximum rating
Stressing the device beyond the
“Absolute Maximum Ratings” may cause permanent damage. The
product is not protected against over-voltage or reversed voltages. If necessary, voltage spikes
exceeding the power supply voltage specification, given in table above, must be limited to values within
the specified boundaries by using appropriate protection diodes.
3.4 Operating conditions
All specifications are at an ambient temperature of 25 ° C. Extreme operating temperatures can
significantly impact specification values. Applications operating near the temperature limits should be
tested to ensure the specification.
Table3.3 operating temperature range
Operating beyond the specified operating conditions can affect device reliability.
Table3.4 Operating power supply range
Operating beyond the specified operating conditions can affect device reliability.
Symbol
Description
Condition
Min
Max.
Unit
3.3Vaux
Module supply
voltage
Input DC voltage at 3.3Vaux pins
–0.3
3.6
V
USB
USB D+/D- pins
Input DC voltage at USB interface pins
3.6
V
SPDT_SEL
Port select
Input DC voltage at SPDT_SEL input pins
–0.3
3.6
V
RESET
MPCI reset input
Input DC voltage at RESET input pin
–0.3
3.6
V
SPI
SPI interface
Input DC voltage at SPI interface pin
–0.3
3.6
V
GPS_PPS
GPS 1 pps input
Input DC voltage at GPS_PPS input pin
–0.3
3.6
V
Rho_ANT
Antenna ruggedness
Output RF load mismatch ruggedness at
ANT1
10:1
VSWR
Tstg
Storage Temperature
–40
85
°C
Parameter
Min.
Typ
Max.
Unit
Remarks
Normal operating
temperature
-20
+25
+65
°C
fully functional and meet 3GPP specifications
Extended operating
temperature
-40
+85
°C
RFperformancemaybeaffected byoutside
normal operating range
Storage Temperature
-40
+125
°C
Symbol
Parameter
Min.
Typical
Max.
Unit
3.3Vaux
operating supply voltage
3.00
3.30
3.60
V