Shenzhen Foxwell Technology Co. Ltd. I70 Manuale Utente

Pagina di 63
30
Figure 4-32 Sample Erase Codes Screen
3.Check the codes again. If any codes remain, repeat the Erase Codes
steps.
4.3.5 Live Data
Live Data menu lets you view real time PID data in text, plot and gauge
formats, learn good sensor data and compare them with faulty data, and
record live data from a selected vehicle electronic control module.
Menu options typically include:
● All Data
● Custom List
4.3.5.1 All Data
All Data menu lets you view all live PID data from a selected control module.
i70 allows you to view live data information in 6 different types of display
modes.
Text Mode - this is the default mode which displays the parameters in
texts.
Graph Mode - displays the parameters in waveform graphs, giving you
the ‘real picture’ of what’s going on in the vehicle. You can view up to 4
parameter graphs simultaneously and easily find and zoom in on a
particular string of data.
Merged Graph Mode - merges multiple PID plots into one coordinate, so
you can easily see how they affect each other, providing you with the
most comprehensive and functional look at live data possible.
Guage Mode - displays the parameters in the form of an analog meter.
Study Mode - gives you the ability to learn good live sensor data values
during idle, KEKO, acceleration, deceleration, part load and heavy load
on each vehicle comes into your shop and records them for future
reference.
Comparison Mode - If that vehicle comes in is with a problem, you can
easily compare the faulty sensor and parameter readings to the good
readings, and you will be alarmed when a faulty sensor reading is
detected.
NOTE
● Study and Comparison modes are available for viewing of parameter
readings in text mode ONLY.
● In case no learned value is stored in the scan tool, the Comparison Mode
will not be available.
To view all live PID data:
1.Press
Live Data from Select Diagnostic Function menu to display the live
data menu.