Metrum Technologies LLC UTILIWISEECM Manuale Utente
8
When the Windows
®
new hardware wizard prompts for driver installation, browse to the Metrum
USB folder where the driver is located. Once installed, follow the steps below.
1. Open Device Manager.
2. Open the Properties window for the Metrum USB.
3. Verify the COM port number for use in the Metrum Configurator application described in
the next section
4. Verify the baud rate is set to 115200.
5. Click "OK" to close the Properties dialog window and exit Device Manager.
Once the USB cable is connected, apply power to the meter if not already powered up and
ensure the LED
’s on the UtiliWise
®
ECM are lit before continuing. On each of the Metrum
Utiliwise
®
ECM’s, there are 4 LED’s placed near each other and labeled D10, D11, D12, and
D13. These LED’s indicate the state of the ECM and are described in the table below.
LED Designator
Description
Normal State
Activity
D10
Power Indicator
Green
blinking
Red
D11
Carrier Detect
Green
Solid
Red
during session
D12
Receive
Green
Blinking
Red
D13
Transmit
Green
Blinking
Red
All four LEDs above blink
Red
simultaneously once the ECM acquires its mobile IP and then every
10 seconds thereafter verifying it has not lost connectivity.
2.1.2. I
NSTALL
M
ETRUM
C
ONFIGURATOR
S
OFTWARE
The Metrum Configurator is the software used to perform a “Settings” check before field
installation of the Utiliwise
®
Endpoint. It is compatible with Microsoft Windows
®
operating
systems 98SE and later. Follow the steps below to install Configurator on your PC.
1. Copy the Configurator folder from the supplied Metrum CD-ROM to the desired location
on your hard drive e.g.
“C:\Program Files\Metrum”.