Chapter 13:  SLR 8000 Wireline 
 
 
 
13.3
 
Board Configuration
 
There are only two options on the Wireline board that must be configured through jumpers. All other 
configuration settings are modified using the CPS. 
 
13.3.1
 
DC Remote Jumper Configuration
 
When operating the Wireline board in DC Remote Control mode, the jumpers on header P1200_3 must 
be set. These jumpers route DC Control currents from the correct Wireline pair to the DC Remote 
Decoder. 
NOTICE: For maximum audio performance, the jumpers should be removed when operating in 
Tone Remote Control or no remote control mode. 
The following table and figure shows the jumper configuration and location of jumpers on the P1200_3 
connector for the Wireline Interface Board. 
 
Table 51: Wireline Board Jumper Settings
 
Header P1200_3 
Jumpers
 
 
No DC Remote 
No jumpers installed 
2-Wire DC Remote 
Jumper pins: 1 to 2, 3 to 4 
 
4-Wire DC Remote 
Jumper pins: 5 to 6, 7 to 8 
NOTICE: Do not simultaneously enable 2-Wire and 4-Wire DC Remote. 
 
Figure 104: Location of Jumpers on the P1200_3 Connector 
 
 
13.3.2
 
E&M Jumper Configuration
 
When operating the SLR 8000 in an E&M configuration through the Wireline board, there are two 
modes to choose from. The E&M mode is selected through the jumper settings on header P2301_1. 
These jumpers select whether the Wireline board PTT function is electrically isolated or 
non-isolated. 
The following table and figure show the jumpers' configuration and location of jumpers on the P2301_1 
connector for the Wireline Interface Board. 
 
Table 52: Wireline Board Jumper Settings
 
Header P2301_1 
Jumpers
 
 
Isolated 
3 to 5, 4 to 6 
Non-Isolated 
Jumper pins: 1 to 3, 2 to 4, 5 to 7, 6 to 8 
 
2 4 6 8
 
1 3 5 7